Normet TamSeal 7 (formerly TamSil 7) — Silicate-Based Penetrating Waterproofing for Concrete
A colourless, water-thin silicate solution that soaks into cured concrete and seals it from within — no membrane to lift, protect or re-coat. Supplied with application guidance by Space Arc across Delhi NCR and Pan India.
What is it?
A modified silicate solution, formerly sold as TamSil 7, that reacts inside concrete to create a permanent, water-insoluble barrier.
Where is it used?
Roofs and podium decks, car parks, road and rail bridge decks, airport pavements, wharf decks, water-retaining structures, façades and precast units.
Why use it?
Fully trafficable after the first application, no future maintenance, and it re-seals new hairline cracks — with no membrane that can tear or debond.
How is it applied?
Cracks flooded first, then the slab sprayed at 4–6 m²/kg, followed by three days of water spraying and a 12-hour pond test.
About Normet TamSeal 7
TamSeal 7 is Normet’s penetrating waterproofer for horizontal concrete — the decks, roofs and slabs where a surface membrane would be walked on, driven over or exposed to weather. Instead of forming a film on top, the solution travels into cracks and pores and reacts with the concrete itself. The treated surface looks unchanged, needs no protective screed, and can carry traffic once the treatment is complete. The product was previously sold as TamSil 7, a name many Indian specifications and suppliers still use.
As Pan India Project Distributor of NORMET, Space Arc Engineering supplies TamSeal 7 and supports contractors with substrate checks, the three-day watering regime and pond testing. We serve projects across Delhi NCR directly and supply material Pan India.
The technical insight
Cured concrete contains free calcium (lime) left over from cement hydration. TamSeal 7 carries dissolved silicate into the capillaries, where it reacts with that free calcium to form calcium silicate hydrate — the same insoluble binder that gives concrete its strength. The new gel fills pores and fine cracks, so the barrier is part of the concrete rather than a layer on it. The TDS backs this with low water absorption (1.1% m/m, ASTM C642), 5.5 mm water penetration (DIN 1048 Part 5), a surface hardness of 6 on the Mohs scale, and very low chloride uptake in the AASHTO T-259 ponding test (0.03% m/m at 13–25 mm depth). Because the reaction depends on free calcium and water, the watering cycles after application are not optional — they drive the reaction. It also explains the mix-design rules: slag-blend and OPC concretes work, Type C fly ash up to 30% is acceptable, but Type F fly ash concrete is not suitable.
Where it is used
- Rooftops and podium decks
- Multi-level and basement car parks
- Road and rail bridge decks
- Airport runways, taxiways and aprons
- Wharf decks and marine structures
- Water-retaining structures
- Tiled areas and shower recesses (not terracotta or glass-glazed tiles)
- Façades and precast elements and panels
Key advantages
- No re-application or ongoing maintenance needed, as per Normet’s TDS
- 100% trafficable after the first application — no protective screed needed
- Re-seals future hairline cracks
- If a stubborn crack shows up, it is easy to find and treat — no membrane to lift
- Colourless, non-toxic and biodegradable; non-flammable
- Low water absorption of 1.1% m/m (ASTM C642) and 5.5 mm water penetration (DIN 1048)
- Raises surface hardness to 6 on the Mohs scale and reduces chloride ingress
- Works on slag-blend and OPC concretes, including Type C fly ash up to 30% of cement
Limitations & considerations
- Concrete must be at least 28 days old, clean and free of curing compounds that block penetration
- Not suitable for working or volatile cracks caused by structural defects or mechanical damage
- Not suitable where segregation and voids are likely, such as construction or pour joints — these need waterstops or injection tubes
- Not suitable for concrete made with Type F fly ash
- Do not apply below +2°C or above +40°C ambient
- Etches glass and corrodes metals: protect glass, aluminium, wood and painted finishes from overspray
Selection & best practice
Check the slab before you order. It should be at least 28 days old, cured with water or an acrylic compound that has degraded within 28 days; wax or chlorinated-rubber curing compounds must be ground or grit-blasted off. Chip out honeycombing, treat it with TamSeal 7 and make good with TamCrete GP or TamCrete 46. Old or carbonated concrete may need a supplementary treatment to restore free calcium — ask us before starting. Detail joints separately: TamSeal R hydrophilic waterstop or an Injection Tube RI system in construction joints, and TamSeal R around drains and penetrations.
On the day, locate every crack and flood it with solution, allowing an extra 1.3 kg per 3 linear metres of crack. Spray the rest of the area at 4–6 m² per kg (about 1.3 kg per 5 m² on average, depending on absorption). When the surface is touch dry, usually after 2–6 hours, flood-spray it with water; repeat on day 2 and day 3. After the third watering, block the drains and pond the area for at least 12 hours to confirm the seal.
Specifications
Values below are as per Normet’s published TDS for TamSeal 7 (Asia edition, V1ASIA18, 2018). Laboratory results; always confirm with a site trial. Pack sizes are not stated in the TDS — ask us for current packs.
| Type | Modified silicate penetrating waterproofing solution (formerly TamSil 7) |
| Colour | Colourless |
| Solids | 25–30% |
| Density at 25°C | 1.225 |
| Viscosity | 15–20 cps |
| Flash point / flammability | Boils at 101°C / not flammable |
| Water absorption (ASTM C642:1997) | 1.1% m/m |
| Water penetration (DIN 1048 Part 5) | 5.5 mm |
| Abrasion resistance (SS301, Mohs scale) | 6 |
| Chloride ion penetration (AASHTO T-259-02) | 0.28% m/m at 1.6–13 mm; 0.03% m/m at 13–25 mm |
| Application rate | 4–6 m²/kg (average 1.3 kg per 5 m²); cracks extra 1.3 kg per 3 linear m |
| Application temperature | +2°C to +40°C ambient; concrete at least 28 days old |
| Storage / shelf life | 4–30°C, dry, out of direct sunlight; one year unopened |
Industry use cases
Car Parks & Podiums
Waterproofing trafficked decks above occupied floors without a membrane that wears under tyres.
Bridges & Flyovers
Penetrating protection for road and rail bridge decks against water and chloride ingress.
Airports
Sealing runway, taxiway and apron pavements where surface coatings are impractical.
Commercial Roofs
Waterproofing flat RCC roofs poured to falls, with no protective screed required.
Ports & Marine
Wharf decks and marine structures exposed to salt water and spray.
Frequently asked questions
Is TamSeal 7 the same as TamSil 7?
How much TamSeal 7 do I need?
Can I apply TamSeal 7 on new concrete?
Does it work on cracks and joints?
Do I need a screed or tiles over it?
Do you supply Normet TamSeal 7 in Delhi NCR?
How we position Normet TamSeal 7
TamSeal 7 is our first choice for trafficked or exposed horizontal concrete — decks, car parks and roofs — where a membrane would wear out. If the structure faces water under pressure, such as tanks, basements or retaining walls, we move to Normet TamSeal 20 crystalline slurry. For flexible coatings under tiles, see TamSeal 10F and TamSeal 5. Surface repairs before treatment can be done with TamCrete GP. Browse everything on our Normet construction chemicals page.
More Normet waterproofing products
Source Normet TamSeal 7 for your project
Pan India Project Distributor of NORMET — product selection, site trials and technical support across Delhi NCR and Pan India.