Sika Waterbar — PVC Waterstop for Waterproofing Construction Joints in Basements, Tunnels, and Water-Retaining Structures

SIKAAuthorised distributor

Sika Waterbar

Extruded PVC waterstop that seals construction and expansion joints from inside the concrete section, keeping water out of basements, tanks and tunnels.

BrandSikaCategoryExpansion JointsFormA flexible, plasticised PVC profile cast into the joints of concrete to form a continuous internal barrier against…

What is it?

A flexible, plasticised PVC profile cast into the joints of concrete to form a continuous internal barrier against water passing through the section.

Where is it used?

Construction and movement joints in water-retaining and water-excluding structures such as basements, tanks, tunnels and pools.

Why use it?

It gives a permanent mechanical seal that does not depend on surface coatings, and keeps working under hydrostatic pressure for the life of the structure.

How is it applied?

The strip is positioned across the joint, tied to the reinforcement so half its width stays in each pour, and cast integrally into the concrete.

About Sika Waterbar

Sika Waterbar is a family of extruded plasticised PVC waterstops used to seal the joints that are unavoidable in cast-in-situ concrete. Wherever one pour meets the next, or wherever a structure has to be allowed to move, there is a plane through which water can travel. A waterstop is embedded across that plane so that half its width sits in the first pour and half in the second, leaving a continuous flexible diaphragm locked inside the concrete. Water trying to migrate along the joint is forced to follow the long, ribbed path of the profile rather than a straight line, and the ribs also key the strip firmly into the surrounding concrete so it cannot be pushed out under pressure.

For engineers and contractors in India, the appeal of Sika Waterbar is that the seal is built into the structure rather than applied to its face. Membranes and coatings can be damaged during backfilling or lost to abrasion and ageing; a cast-in waterstop is protected inside the concrete section from day one. The range covers both construction joints, where movement is negligible, and expansion joints, where a central bulb lets the two halves of the structure move apart and back without tearing the seal. It is the reason basements, underground tanks, sewage works and tunnel linings can be built in stages and still behave as a single watertight box.

The technical insight

The performance of a PVC waterstop comes down to two things working together: an extended sealing path and mechanical anchorage. The moulded ribs on each wing multiply the distance water must travel to cross the joint, and because that path is long and tortuous rather than direct, the pressure gradient driving the water is spread out and the flow effectively stalls. Those same ribs are gripped by the concrete on both sides, so the strip is anchored against the hydrostatic head trying to blow it out of the joint. On expansion profiles a hollow centre bulb sits directly over the joint gap; as the structure opens and closes, the bulb flexes and takes up the movement while the wings stay locked in the concrete, so the seal accommodates joint travel without straining the anchorage. The plasticised PVC compound is formulated to stay flexible across a wide service-temperature band, which is what lets the material keep sealing decade after decade instead of hardening and cracking.

Where it is used

  • Construction joints in basement rafts and retaining walls
  • Expansion and movement joints in water-retaining structures
  • Underground and elevated water storage tanks and reservoirs
  • Sewage and effluent treatment plant structures
  • Road, rail and metro tunnel linings and cut-and-cover boxes
  • Swimming pool shells and water features
  • Bridge abutments, piers and box structures
  • Podium slabs, lift pits and other below-grade concrete

Key advantages

  • Seal is cast inside the concrete, so it is protected from backfill damage and ageing
  • Continuous ribbed profile creates a long, tortuous path that resists water under head
  • Expansion profiles with a centre bulb absorb structural movement without tearing
  • Plasticised PVC stays flexible across a wide service-temperature range
  • Profiles and welded corner/junction fittings give an unbroken run around the structure
  • Works independently of surface membranes, adding a second line of defence
  • Range of widths lets the profile be matched to wall thickness and water head
  • Proven, well-understood technology that consultants readily approve

Limitations & considerations

  • Must be positioned and cast integrally with the concrete — it cannot be added to a joint after the pour
  • Site joints in the profile must be heat-welded correctly; poor welds are a common leak source
  • Displacement or folding during concrete vibration will compromise the seal
  • The correct profile type (construction vs expansion) and width must be selected for the joint and water head
  • Does not waterproof the concrete face itself — cracking or honeycombing away from the joint needs separate treatment

Selection & best practice

Choose the profile to suit the joint: a flat, ribbed section for construction joints with little movement, and a centre-bulb section for expansion joints that have to move. Position the waterstop so its centreline sits exactly on the joint, with half the width in each pour, and support it clear of the shutter using bar chairs or clips. Tie it to the reinforcement at roughly 300 mm centres with binding wire so it cannot shift or fold when concrete is placed and vibrated. Form all corners, tees and junctions with factory or heat-welded fittings rather than site-butted cuts, and inspect every weld for a continuous molten bead before casting. During concreting, work the concrete carefully around and beneath the profile to avoid trapping voids that would create a leakage path.

Specifications

Material Plasticised polyvinyl chloride (PVC-P), UV and chemical resistant
Profile types Flat/ribbed (construction joints) and centre-bulb (expansion joints)
Available widths 150, 200, 230, 240 and 300 mm
Tensile strength ≥ 10 N/mm² (DIN 53504)
Elongation at break ≥ 380% (DIN 53504)
Shore A hardness 62 ± 5 (DIN 53505)
Tear strength ≥ 8 N/mm² (DIN 53507)
Reference standard DIN 7865 (PVC waterstops for joints in concrete)
Installation Cast integrally into the joint; heat-welded corner and junction fittings

Industry use cases

Basements & Below-Grade

Cast-in across raft and wall construction joints so a staged basement pour behaves as one watertight box against groundwater.

Water & Wastewater

Seals joints in reservoirs, clear-water tanks and sewage treatment structures where leakage is not acceptable in either direction.

Tunnels & Metro

Runs through construction and movement joints of cut-and-cover boxes and tunnel linings to keep the structure dry under head.

Pools & Water Features

Provides a permanent internal seal at joints in swimming pool shells and architectural water bodies.

Bridges & Infrastructure

Waterproofs joints in abutments, piers and box structures exposed to standing or percolating water.

Frequently asked questions

What is the difference between the flat and centre-bulb Sika Waterbar profiles?
The flat, ribbed profile is for construction joints where the concrete is not expected to move. The centre-bulb profile has a hollow bulb over the joint gap that flexes as the structure expands and contracts, so it is used for expansion and movement joints.
Which width should I specify?
Width is chosen to suit the wall or slab thickness and the water head the joint will see. Sika Waterbar is available in 150, 200, 230, 240 and 300 mm; heavier heads and thicker sections generally call for the wider profiles. Share your joint detail and head with us and we will advise.
Can a waterstop be fitted after the concrete is poured?
No. A cast-in PVC waterstop has to be positioned across the joint before concreting so that it is embedded in both pours. If a joint has already been cast, a surface or re-injectable system is the appropriate remedy instead.
How are corners and junctions handled?
Corners, tees and crosses should be made with factory or heat-welded fittings so the profile runs unbroken around the structure. Butting site-cut pieces together at a corner is a common cause of leaks and should be avoided.
Does the waterstop make the whole concrete watertight?
It seals the joints, which are the usual weak points, but it does not waterproof the concrete face. Cracking, honeycombing or porous concrete away from the joint needs a waterproofing admixture, crystalline treatment or membrane in addition.
Does Space Arc supply Sika Waterbar across India?
Yes. As an authorised distributor and applicator we supply the Sika Waterbar range in Delhi NCR and pan-India, and can help you select the right profile, width and welded fittings for your joint layout.

How we position Sika Waterbar

Sika Waterbar sits in Sika’s joint-sealing line-up alongside Sika swellable waterstops and SikaSwell profiles for tight or congested joints, and Sikadur and Sikaflex sealants for the surface side of movement joints; for whole-structure watertightness it pairs naturally with Sika waterproofing admixtures and Sikalastic membranes. Where a project is standardised on Fosroc, the equivalent cast-in PVC waterstop is the Supercast PVC range, and complementary Fosroc systems such as Nitobond, Renderoc and Conbextra can complete the joint and repair scope. Space Arc supplies both families and can match the waterstop to whatever the rest of the specification calls for.

Preferred brand · Fosroc equivalent

Fosroc Supercast PVC Waterstop — A specifier standardised on Fosroc, or needing Fosroc’s fully-continuous multi-bulb profiles and brass-eyelet fixing, would choose the Supercast PVC range as the direct cast-in equivalent.

Compare with Fosroc Supercast PVC Waterstop →

Source Sika Waterbar for your project

Authorised distribution, technical advice & professional application across Delhi NCR and Pan-India.


Scroll to Top