Normet TamCrete MFC / SFC — Microfine Portland Injection Cement for Rock and Soil Grouting
Microfine cements ground from pure Portland clinker that penetrate tight fissures and set faster than OPC, for pre- and post-excavation grouting in tunnels, caverns and mines. Supplied with mix and grade guidance by Space Arc across Delhi NCR and Pan India.
What is it?
A family of microfine Portland cements — MFC Rapid, MFC Fast, MFC Standard and SFC — ground to a Blaine fineness above 625 m²/kg for injection grouting.
Where is it used?
Rock-mass grouting for tunnels, caverns and mines, soil injection for stabilisation and water sealing, consolidating fractured rock, and concrete crack injection.
Why use it?
Very fine grains (d95 under 16–25 µm) get into tight fissures; all grades gel and set faster than OPC, and they work with standard cement injection pumps.
How is it applied?
Mixed at water/cement 0.8–1.2 with TamCem superplasticiser in a high-speed colloidal mixer, kept agitated, and injected within 20–60 minutes by piston pump.
About Normet TamCrete MFC / SFC
TamCrete MFC and TamCrete SFC are Normet’s microfine cements for injection. They are ground from pure Portland cement clinker to a very high fineness, and are used with TamCem superplasticisers so that the slurry flows into narrow joints and fissures and leaves a watertight, grouted rock mass. Four grades let the grouting engineer trade setting speed against open time: MFC Rapid and MFC Fast for quick gel and early strength, MFC Standard and SFC for longer working times. Production and quality control follow EN 197-2 and ISO 9001.
Space Arc Engineering supplies TamCrete MFC and SFC as Pan India Project Distributor of NORMET. We help tunnelling and ground-engineering teams choose the grade, set up trial mixes with TamCem admixtures, and plan supply in bags or bulk bags for projects across Delhi NCR and Pan India.
The technical insight
Whether a cement grout enters a fissure depends on its largest particles, not its average size. TamCrete MFC Rapid and Fast have 95% of particles below 16 µm, MFC Standard below 20 µm and SFC below 25 µm, with d50 values of under 5, 7.5 and 10 µm respectively. Combined with a superplasticiser to keep the grains dispersed, this lets the slurry permeate joints that ordinary cement would block at the entry. The fineness also speeds up hydration: in Normet’s 1:1 water/cement lab tests, initial gel ranged from 30–45 minutes (Rapid) to 150–250 minutes (SFC), and 28-day compressive strength reached about 15 MPa for the MFC grades and about 12 MPa for SFC. Bleeding stays below 2% for Rapid and Fast and below 5% for Standard and SFC, so the grout fills the void rather than separating. Set time can be tuned further with the TamCem superplasticiser dose or TamCem HCA hydration control.
Where it is used
- Pre-excavation and post-excavation rock-mass grouting in tunnels
- Grouting caverns, shafts and underground mines
- Ground-water sealing around excavations
- Ground stabilisation by soil injection
- Consolidating weak and fractured rock
- Concrete crack injection
- Sealing water channels
- Curtain and consolidation grouting where cement-based grouts are specified
Key advantages
- Standard cement injection equipment can be used
- Superior penetration into rock fissures from microfine grading (d95 under 16–25 µm by grade)
- Fast initial gel and setting compared with OPC, cutting waiting time before the next activity
- Higher strengths achievable than with chemical grouts, as per the TDS
- Greater penetration gives a more watertight grouted mass
- Low bleeding: under 2% (Rapid, Fast) and under 5% (Standard, SFC)
- Better working environment, with no hazardous components
- Four grades to match set time to the grouting method
Limitations & considerations
- Needs a high-speed colloidal mixer (minimum 1,500 rpm) for proper dispersion; mixing time no more than 4 minutes
- Grout must be kept under constant agitation and not held in the agitator longer than 30 minutes unless extended with TamCem HCA
- Inject within 20–60 minutes of mixing depending on grade
- The published lab data are for 1:1 water/cement slurries with TamCem admixture — site mixes need their own trials
- Store dry at 10–45°C; shelf life six months in unopened packs
- Specific MFC/SFC versions and mix designs should be confirmed with us and Normet for each project
Selection & best practice
Pick the grade from the time window you need. MFC Rapid suits short injection holes and quick turnarounds; MFC Fast gives a little more time; MFC Standard and SFC give longer gel and set times for long stages or bigger grouting rounds. Keep the water/cement ratio between 0.8 and 1.2 by weight.
Batch in this order: water and superplasticiser into the mixer, then cement, mixing for 2–3 minutes; add TamCem HCA and mix for 1 minute if a longer open time is needed; then transfer to the agitator tank. Use a colloidal mixer of at least 1,500 rpm and keep total mixing under 4 minutes. Inject by high-pressure piston pump within 20–60 minutes, and do not hold grout in the agitator for more than 30 minutes unless HCA has been added. Check Marsh cone run-out (31–35 s for all grades) and mud balance density (1.45–1.50 kg/l) at the plant.
Specifications
Values below are as per Normet’s published TDS for TamCrete MFC / SFC (Global edition, V1WW22, 2022). Lab data for a 1:1 water/cement slurry with TamCem admixture, mixed in a high-colloidal mixer. Figures shown in the order MFC Rapid / MFC Fast / MFC Standard / SFC.
| Type | Microfine Portland injection cement ground from pure clinker; Blaine > 625 m²/kg |
| Grain size d50 | < 5 / < 5 / < 7.5 / < 10 µm |
| Grain size d95 | < 16 / < 16 / < 20 / < 25 µm |
| Marsh cone run-out after mixing | 31–35 s for all grades |
| Initial gel | 30–45 / 70–110 / 120–180 / 150–250 min |
| Initial set (50 kPa shear strength) | 45–75 / 90–150 / 180–300 / 200–350 min |
| Maximum bleeding | < 2% / < 2% / < 5% / < 5% |
| Mud balance density | 1.45–1.50 kg/l for all grades |
| Compressive strength 1 day / 2 days / 28 days | ~5 / ~10 / ~15 MPa (Rapid, Fast); ~4 / ~7 / ~15 MPa (Standard); ~3 / ~5 / ~12 MPa (SFC) |
| Water/cement ratio (by weight) | Normally 0.8–1.2 |
| Quality control | EN 197-2 and ISO 9001 |
| Packaging | 20 kg bags or 1,000 kg bulk bags |
| Storage / shelf life | 10–45°C, dry, out of direct sunlight; six months unopened |
Industry use cases
Metro & Road Tunnels
Pre-excavation probe-hole grouting and post-excavation sealing to control ground-water inflow.
Hydropower & Caverns
Consolidation and curtain grouting of fractured rock around caverns and pressure tunnels.
Underground Mining
Sealing water-bearing zones and consolidating weak rock around development headings.
Ground Engineering
Soil injection for stabilisation and ground-water sealing at deep excavations.
Structural Repair
Cement-based injection of cracks in mass concrete where resin grouts are not wanted.
Frequently asked questions
What is the difference between TamCrete MFC and SFC?
Which MFC grade should I use?
What water/cement ratio is used for microfine cement grout?
Can I use my existing cement grouting pumps?
How long can the mixed grout be kept?
Who supplies Normet TamCrete MFC in India?
How we position Normet TamCrete MFC / SFC
TamCrete MFC / SFC is our recommendation for cement-based rock grouting where joints are too tight for ordinary cement. For fine sands and soils, step to the slag-based Normet TamCrete UFC ultrafine range. Where flowing water must be stopped fast or very fine cracks remain, pair cement grouting with polyurethane resins such as TamPur 150 or acrylic gels such as TamAcryl 2000. Admixtures for the mix, including TamCem superplasticisers, are on our Normet construction chemicals page.
More Normet injection products
Source Normet TamCrete MFC / SFC for your project
Pan India Project Distributor of NORMET — product selection, site trials and technical support across Delhi NCR and Pan India.