Tile on Tile Adhesive for Refurbishment Projects

The problem on site

Tile replacement during renovation is one of the most disruptive phases of any building refurbishment. In commercial spaces, hospitals, offices, and occupied residential buildings across India, breaking out old floor and wall tiles creates immediate complications for site engineers and contractors.

The standard practice of hacking out old tiles demands heavy manual labor or mechanical chipping tools. This process creates excessive noise and heavy clouds of dust, which often violates building quiet hours and upsets nearby occupants. It also produces large volumes of hard rubble that must be bagged, transported down elevators or stairs, and hauled away from the site at considerable cost.

Beyond the logistical burden, mechanical hacking carries a serious risk of damaging the underlying base concrete or brickwork. If an existing waterproofing membrane lies beneath the screed or plaster, chipping out the old tiles can puncture or debond it, introducing leak pathways that did not exist before the renovation began. When deadlines are tight, spending several days merely stripping and repairing a substrate delays project handovers and drives up site costs.

Why it happens

Contractors often consider laying new tiles directly over the old layer to avoid demolition, but attempts using conventional methods frequently fail. Understanding the physical mechanics of the substrate explains why this occurs.

Traditional site-mixed sand and cement mortar depends entirely on mechanical interlock to establish a bond. Standard masonry substrates, such as concrete blocks, brickwork, or porous cement screeds, have open capillary pores. When a wet cement slurry or mortar is placed against them, it penetrates these tiny voids. As the cement hydrates and hardens, it locks mechanically into the surface.

Old glazed ceramic and vitrified tiles present the opposite surface condition. They are dense, vitreous, and non-porous. Their factory-applied glaze or polished finish forms a smooth barrier that prevents water absorption. When a standard cement-sand mix is applied over an old tiled surface, the paste cannot penetrate the glaze. There are no pores to create a mechanical key.

On wall applications, the problem becomes visible immediately. Standard mortar lacks slip resistance on non-porous surfaces. Under the gravitational pull of its own weight, a new tile placed on a vertical glazed wall will slide downwards before the cement begins to set. Even if propped up during installation, the lack of chemical adhesion means that once the mortar dries and undergoes normal thermal movement or vibration, the new tile will delaminate and pull away completely.

How Space Arc Engineering approaches it

Avoiding the delay of demolition requires a systematic approach rather than guesswork on site. Space Arc Engineering acts as an authorised project distributor and technical partner to help contractors implement a dependable tile-over-tile method.

The first step recommended by Space Arc Engineering is a thorough assessment of the existing tiled substrate. Not every old floor or wall can receive a direct overlay. Our team advises site engineers on how to conduct simple tapping and sounding tests across the entire area to detect hollow-sounding sections. Any existing tile that has lost its bond with the original screed or wall plaster must be isolated and rectified first, as no overlay can perform well over an unstable base.

Once the base integrity is confirmed, Space Arc Engineering provides guidance on mechanical cleaning to remove surface contaminants such as grease, soap films, curing waxes, and dust that interfere with adhesion. Space Arc Engineering then supplies engineered tile on tile adhesive formulations specifically designed to create high chemical and mechanical bond strength against non-porous surfaces.

The system we supply

To solve the challenge of laying tiles over existing glazed finishes without vertical slippage, Space Arc Engineering supplies Sika SikaCeram-212 Non-Slip, manufactured by Sika.

Sika SikaCeram-212 Non-Slip is a factory-prepared, polymer-modified cementitious tile adhesive designed for demanding installations. Because it contains selected aggregates, high-grade cements, and specific chemical polymers, it bridges the gap between the smooth existing glaze and the back of the new tile.

Key technical characteristics of this system include:

  • Non-slip performance: The thixotropic properties engineered into the formulation prevent tiles from sliding down walls, allowing masons to work from the top down or bottom up without continuous mechanical support.
  • Extended workable adjustment: The adhesive provides over thirty minutes to adjust the position of placed tiles, allowing your installation team sufficient time to align joints and maintain neat lines across large wall areas.
  • Broad tile compatibility: The polymer bond suits ceramic and vitrified tiles across both interior floor and wall surfaces.
  • High bond integrity: The polymer additives provide the necessary chemical adhesion to grip vitreous, low-porosity surfaces securely without relying solely on capillary absorption.

As an authorised distributor, Space Arc Engineering ensures that the material delivered to your project is sourced directly through official channels, backed by manufacturer batch control and technical documentation.

What to check before you order

Before placing an order for Sika SikaCeram-212 Non-Slip, your site supervisory team should confirm the following technical parameters:

  • Substrate soundness: Tap every existing tile with a wooden mallet or sounding rod. Remove any hollow, loose, or cracked tiles, and fill the resulting depressions with a compatible repair mortar so the surface is flush.
  • Surface cleanliness: Ensure the existing glazed tiles are degreased, scrubbed clean with water, and allowed to dry completely before applying the adhesive bed.
  • Finished floor levels: Adding a second layer of tile raises the floor elevation. Check clearances below door leaves, transition thresholds to adjacent rooms, and plumbing fixture heights to ensure the buildup can be accommodated.
  • Tile dimensions: Verify the size, thickness, and material type of the new tiles with the Space Arc Engineering technical team to confirm that the chosen notched trowel size matches the application requirements.
  • Movement joints: Note the locations of existing expansion or perimeter movement joints in the structure, as these joints must be mirrored up through the new tile installation.

Talk to our technical team

Space Arc Engineering helps contractors, builders, and project managers select the correct materials and application procedures for refurbishment works. If you are planning a renovation project and need technical advice on tile on tile adhesive selection, surface preparation, or on-site testing, contact our team directly.

Call Space Arc Engineering on +91 99991 55255 or +91 72900 89007 to discuss your site specifications. You can also visit www.space-arc.in or browse our full range of construction systems at our solutions.

Products for this job, supplied by Space Arc

Need help choosing? Ask our team for a quote.

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top