NORMETPan India Project Distributor

Normet TamPur 120 — Two-Component High-Strength Polyurethane Grout

A two-part rigid polyurethane that reaches over 60 MPa restrained compressive strength. Fast-set for cutting off heavy inflows, slow-set for deep penetration into fine fissures, slab stabilisation and ground consolidation. Potable water certified, as per Normet’s TDS.

BrandNormetCategoryInjection resins & micro cementsFormTwo-component liquid (polyol A + MDI B), 1:1 by volume

What is it?

A two-component polyurethane grout (polyol plus polymeric MDI) that cures into a tough, rigid, hydrophobic and chemical-resistant solid.

Where is it used?

Heavy water ingress, small voids, stabilising concrete slabs, ground consolidation and grouting of wet or dry fissures.

Why use it?

Restrained compressive strength above 60 MPa, high bond strength, and a choice of fast or slow set for the same chemistry.

How is it applied?

Injected 1:1 by volume through a two-component pump with a static in-line mixer at least 500 mm long.

About Normet TamPur 120

Normet TamPur 120 is the high-strength polyurethane in the range. It is supplied as two ready-to-use parts: a clear polyol (Part A) and a brown polymeric MDI (Part B). Once mixed, they form a hard, rigid polyurethane that resists a wide range of chemicals. Because it cures by reaction between the two parts, it does not need water to set, so it can also be used in dry fissures and under slabs.

The fast-set version reacts in about two minutes and is used to shut off large leaks. The slow-set version stays open for close to an hour, giving time for the grout to travel into fine voids and fissures. Space Arc Engineering supplies TamPur 120 as the Pan India Project Distributor of NORMET, with technical support for trials and site set-up.

The technical insight

TamPur 120 behaves very differently in dry and wet conditions, and that is the key to specifying it. In dry ground, the standard grade expands only about 10% unrestrained, so it acts as a dense, load-bearing grout. When it meets water, the same mix foams strongly (unrestrained expansion over 1500%) to fill the flow path and block the leak. Restrained, the cured material exceeds 60 MPa in compression. In Normet’s tests at 25°C, the standard grade reacted in 125 seconds dry and 112 seconds wet, while the slow-set dry grade took 50 minutes. This gives engineers one product family for both water cut-off and structural filling, provided the right grade is chosen.

Where it is used

  • Cutting off heavy water inflows in tunnels and shafts
  • Filling small voids behind or under concrete
  • Stabilising concrete slabs and filling voids beneath them
  • Ground consolidation in loose or fractured strata
  • Wet fissure grouting where water is present
  • Dry fissure grouting with the slow-set grade for deep penetration
  • Strengthening around pipe and service penetrations
  • Grouting where contact with drinking water is a concern (potable water certified per TDS)

Key advantages

  • Restrained compressive strength above 60 MPa
  • High bond strength and resistance to many chemicals
  • Potable water certified (as per Normet’s published TDS)
  • Fast set (about 2 minutes) or slow set (about 50–60 minutes) to suit the job
  • Low expansion in dry conditions for dense, structural filling
  • Strong foaming in wet conditions for water cut-off
  • Solvent free
  • Ready-to-use 1:1 by volume mix ratio

Limitations & considerations

  • Needs a two-component pump and a static mixer of at least 500 mm; it cannot be hand-mixed
  • Large voids should be filled in stages to limit heat build-up; for big cavities Normet suggests TamPur 117
  • Both parts should be above 15°C before use, ideally conditioned for 12 hours
  • Risk of crystallisation below 10°C on a falling thermometer
  • Rigid when cured, so it is not meant for joints that keep moving
  • TDS data are from lab tests; site reaction depends on temperature and water volume

Selection & best practice

Decide first whether the job is a water cut-off (choose fast set) or penetration and strengthening (choose slow set). Condition both parts to working temperature for at least 12 hours and keep them above 15°C. Use a two-component pump at 1:1 by volume with a static in-line mixer at least 500 mm long, so the parts are fully blended before they reach the packer.

For void filling, work in lifts so heat from the reaction can escape between stages. For slab stabilisation, monitor slab level and adjacent joints during injection and stop at refusal. Store packs between 10°C and 38°C, dry and out of direct sun.

Specifications

ChemistryTwo-component hydrophobic polyurethane: polyol (A) + polymeric MDI (B)
ColourPart A clear; Part B brown
DensityPart A 1.05; Part B 1.23 (at 25°C)
Viscosity at 25°CPart A 450–550 cps; Part B 200–250 cps
Flash point (approx.)Part A > 180°C; Part B > 225°C
Mix ratio1:1 by volume
Reaction time, standard setDry: 180 s at 15°C, 125 s at 25°C; wet: 150 s at 15°C, 112 s at 25°C
Reaction time, slow set (dry)60 minutes at 15°C; 50 minutes at 25°C
Unrestrained expansionAbout 10% dry (standard and slow set); > 1500% wet (standard set)
Compressive strength (restrained)> 60 MPa
Packaging45 kg packs
Storage / shelf life10–38°C, dry, out of direct sunlight; one year unopened

Values as per Normet’s published TDS (Global edition, V1WW20 dated 22 Dec 2020). Figures are typical laboratory results; we recommend a site trial to confirm suitability.

Industry use cases

Tunnels & Shafts

Shutting off heavy inflows at the face or through lining defects with the fast-set grade.

Industrial & Warehouse Floors

Filling voids and stabilising rocking or settled slabs.

Water Supply Structures

Grouting in and around structures where potable water certification matters.

Foundations & Ground Works

Consolidating loose strata and grouting fissures with the slow-set grade.

Frequently asked questions

What is the difference between fast-set and slow-set TamPur 120?
Fast set reacts in about two minutes and is used to stop large leaks. Slow set stays workable for about 50–60 minutes so the grout can travel into fine voids and fissures.
How strong is TamPur 120?
Normet’s TDS gives a restrained compressive strength above 60 MPa.
Does TamPur 120 need water to cure?
No. It is a two-part system that cures by reaction between the parts. In dry conditions it expands only about 10%; in contact with water it foams strongly to seal the leak.
Is TamPur 120 suitable near drinking water?
Normet’s TDS lists it as potable water certified. Share your project’s approval requirements with us and we will help with the documentation.
Can it be used to stabilise a concrete floor slab?
Yes. Slab stabilisation and filling small voids are listed uses. Large cavities should be filled in stages or with a dedicated void-filling product.

How we position Normet TamPur 120

Choose TamPur 120 when the brief needs strength as well as water control: slab stabilisation, ground consolidation or heavy inflows where a dense, load-bearing grout is wanted. For a quick single-part water stop with catalyst control, TamPur 100 is simpler. For a two-part rigid grout from the phthalate-free ECO line, compare TamPur 125 (ECO Range). If cracks or joints will keep moving, a semi-flexible grade such as TamPur 130 (ECO Range) or TamPur 136, or the elastic TamPur 150 (ECO Range), is the better fit. For consolidating rock and coal with a non-foaming resin, use TamPur 116T. Fine soil injection is better served by TamCrete MFC/SFC or TamCrete UFC. Browse the full Normet range or our waterproofing solutions.

Not sure which grade fits? Send us photos of the leak or ground condition, the flow rate and the site temperature. Our team will suggest a grade and help plan a trial.

Source Normet TamPur 120 for your project

Pan India Project Distributor of NORMET. Technical support for trials, dosage optimisation and site support across Delhi NCR and Pan India.

Scroll to Top