Normet TamAcryl 3000 (ECO Range) — Polymer-Reinforced Acrylic Injection Gel for Joints and Leaks
A low-viscosity acrylic resin with a polymer extender that cures into a tougher, more resilient gel gasket — suited to expansion joints as well as cracks, cold joints and injection tubes. Supplied with dosing and pump guidance by Space Arc across Delhi NCR and Pan India.
What is it?
A hydrophilic acrylic injection resin from Normet’s ECO Range (formerly TamAcryl 3000), polymer-extended to give a highly resilient flexible gel.
Where is it used?
Expansion joints, leak sealing in cracks, construction and cold joints, injection tubes, primary or second-pass injection, and soil stabilisation.
Why use it?
Polymer reinforcement gives a gel suited to moving joints, with strong reversible swelling (+39% in wet-dry cycling) and watertightness at 2 bar.
How is it applied?
Part C dissolved into Part B on site; Part A (with 2–8% accelerator) and Part B/C pumped 1:1 by volume with a twin-piston pump.
About Normet TamAcryl 3000
TamAcryl 3000 (ECO Range) is the reinforced member of Normet’s acrylic injection gel family. Like other acrylics it is water-based and very fluid before it reacts, so it penetrates fine cracks and joints. The difference is the polymer extender: it produces a more resilient, flexible gel gasket that copes with movement, which is why Normet positions it for expansion joints as well as for ordinary leak sealing, primary and second-pass injection, and injection tubes. It is tested to EN 1504-5 for CE marking.
Space Arc Engineering supplies TamAcryl 3000 as Pan India Project Distributor of NORMET. We advise on accelerator dosage, site mixing of Part C and pump selection, and support contractors on projects across Delhi NCR with material supply Pan India.
The technical insight
The system has three resin parts and an accelerator. Part C, a powder, is dissolved into Part B on site; the accelerator is mixed into Part A. When the A side and the B/C side meet at 1:1 by volume, the acrylic polymerises around the dissolved polymer, giving a reinforced gel rather than a plain one. The practical effect shows in the BS EN 14498 results: after 10 wet-dry cycles (Regime B) TamAcryl 3000 still gains about 39% in volume, compared with about 6% for the unreinforced TamAcryl 2000 — so it keeps swelling back into a joint that opens and closes. Mixed viscosity is 15–25 mPa·s, still very low, and gel time is set by the accelerator from 60–150 seconds at 2% to under 10 seconds at 8% (lab, 20°C). BS EN 14068 testing showed it watertight at 2 bar and after 500 cycles.
Where it is used
- Expansion joints that need a resilient, reinforced gel
- Sealing water leaks through cracks in concrete and masonry
- Construction joints and cold joints
- Injection tube (re-injectable hose) systems
- Permanent primary injection
- Secondary injection to tighten up earlier work
- Soil stabilisation by injection
- Tunnels, basements and underground structures subject to movement
Key advantages
- Polymer-reinforced gel with high performance suited to expansion joints
- Strong reversible swelling: +39% volume after 10 wet-dry cycles (BS EN 14498 Regime B)
- Watertight at 2 bar and after 500 cycles (BS EN 14068)
- Ultra-low viscosity: 15–25 mPa·s mixed (EN ISO 3219)
- Adjustable gel time from under 10 s to 150 s with 2–8% accelerator
- Reacts even in mineral and saline water conditions
- Good chemical resistance; contains anti-corrosion agents
- Water-based ECO Range product, tested to EN 1504-5 for CE marking
Limitations & considerations
- Part C must be fully dissolved in Part B on site before use
- Needs a suitable pump — ideally stainless-steel twin-piston with a flush unit
- Once accelerator is added to Part A, use within 24 hours
- Condition the material to temperature for at least 12 hours before use
- Gel times in the TDS are lab values at 20°C — confirm by cup test on site
- Store at 4–30°C, dry and out of direct sunlight; shelf life one year unopened
Selection & best practice
Dissolve Part C into Part B first. Then set the accelerator dose by a cup test: pour equal amounts of Part A (with 2–8% accelerator) and Part B/C into two cups, pour back and forth until it gels, and time it. Normet’s guide: about 2% for 60–150 seconds, 3% for 25–60 seconds, 4% for 15–25 seconds, 6% for 10–15 seconds and 8% for under 10 seconds.
Inject at 1:1 by volume, ideally with a stainless-steel twin-piston pump with a flush unit. Condition materials for 12 hours beforehand, use accelerated Part A within 24 hours, and clean the pump with water before the resin sets. For expansion joints, plan the packer layout so the gel fills the full joint depth, and allow for re-injection through tubes where movement is expected.
Specifications
Values below are as per Normet’s published TDS for TamAcryl 3000 (ECO Range) (United Kingdom edition, V1UK23, 2023). Laboratory results; always confirm with a site trial.
| Type | Water-based, polymer-extended hydrophilic acrylic injection gel (ECO Range; formerly TamAcryl 3000) |
| Viscosity, mixed (EN ISO 3219) | 15–25 mPa·s (Part A 30–60 mPa·s) |
| Non-volatile matter, mixed (EN ISO 3251) | > 25% (Part A 40–45%) |
| Density, mixed (EN ISO 2811) | 1.13 g/ml (Part A 1.20 g/ml) |
| Volume / weight change (BS EN 14498) | Regime A, 336 h: +48% / +49%; Regime B, 10 cycles: +39% / +39% |
| Water tightness (BS EN 14068) | Watertight at 2 bar; watertight after 500 cycles |
| Accelerator dose and gel time | 2% → 60–150 s; 3% → 25–60 s; 4% → 15–25 s; 6% → 10–15 s; 8% → under 10 s (200 ml at 20°C, lab) |
| Mix ratio | Part A : Part B (with Part C dissolved) = 1:1 by volume |
| Yield | 1 kg = 0.92 litres |
| Standards | Tested to EN 1504-5 (CE marking) |
| Packaging | 50 kg pack (51.5 kg with accelerator): Part A 25 kg, Part B 25 kg, Part C 1.5 kg, accelerator 1 kg |
| Storage / shelf life | 4–30°C, dry, out of direct sunlight; one year unopened |
Industry use cases
Metro & Road Tunnels
Sealing leaking expansion and segment joints where the lining moves with temperature and load.
Basements & Underpasses
Injecting expansion and construction joints in basements, car parks and road underpasses.
Water-Retaining Structures
Reinforced gel injection at movement joints in tanks and reservoirs.
Injection Tube Systems
Primary and repeat injection of pre-installed hoses in joints.
Ground Engineering
Soil stabilisation where a tougher acrylic gel is preferred.
Frequently asked questions
What makes TamAcryl 3000 different from TamAcryl 2000?
Can TamAcryl 3000 be used in expansion joints?
How is TamAcryl 3000 mixed?
What gel time can I get?
What pack sizes are available?
Who supplies Normet TamAcryl 3000 in Delhi NCR?
How we position Normet TamAcryl 3000
We specify TamAcryl 3000 where an acrylic gel has to live with movement — expansion joints, segment joints and injection tubes in moving structures. For static cracks and cold joints, Normet TamAcryl 2000 is the standard choice. To stop heavy inflows first, use polyurethane resins such as TamPur 150 or TamPur 130. For cement-based ground grouting, see TamCrete UFC. See the full range on our Normet construction chemicals page.
More Normet injection products
Source Normet TamAcryl 3000 for your project
Pan India Project Distributor of NORMET — product selection, site trials and technical support across Delhi NCR and Pan India.