Dr. Fixit Foamshield

DR. FIXITAuthorised distributor

Dr. Fixit Foamshield

Two-component spray PU foam that insulates and waterproofs Indian terraces, cold stores and tanks in a single jointless pass.

BrandDr. FixitCategoryWaterproofingFormA two-component, CFC- and HCFC-free, polymeric MDI-based rigid polyurethane foam system that is spray-applied on site…

What is it?

A two-component, CFC- and HCFC-free, polymeric MDI-based rigid polyurethane foam system that is spray-applied on site to form a seamless, fully bonded 25-30 mm thermal insulation layer, executed as per IS 12432 (Part 3).

Where is it used?

RCC terraces and podium roofs, cold storage envelopes, pre-engineered building roofs and insulated water or process tanks — almost always on large commercial, institutional or industrial projects rather than small residential jobs.

Why use it?

It cuts heat gain through the roof slab (thermal conductivity of just 0.023 W/mK), leaves no seams or joints for water to track through, and adds real compressive strength without loading the structure the way rigid board insulation with a separate membrane does.

How is it applied?

Sprayed by a Pidilite-trained applicator crew using heated plural-component equipment (Graco or Jaguar-type machines) over a cured waterproofing basecoat, built up in 10-15 mm rise passes to the specified thickness, and covered with a UV-stable protective topcoat within 24 hours of spraying.

About Dr. Fixit Foamshield

Dr. Fixit Foamshield sits in a different bracket from the rest of the Dr. Fixit range most homeowners know — it isn’t a bucket you brush or roll on a weekend. It’s a plant-and-crew system: two drums (a 250 kg Part A activator and a 210 kg Part B base), fed through heated hoses into a spray gun by a certified applicator team, reacting on contact to expand into a rigid closed-cell foam that bonds directly to the substrate. Because the foam is fully adhered rather than loose-laid like an EPS or XPS board, there’s no air gap for water to migrate sideways under it if the top membrane is ever nicked — a real point of failure in board-and-membrane systems that Foamshield’s monolithic, jointless build avoids by design. It goes down over an already-cured waterproofing basecoat (Dr. Fixit’s own Wonderproof 100, Superseal 4500 PUH or Superseal 500 GC are the specified options), not directly onto bare concrete, which makes it explicitly a two-layer waterproofing-plus-insulation build rather than a standalone waterproofing coat.

For Delhi NCR and most of India’s climate, the case for Foamshield is really a heat-load argument as much as a leak-prevention one. Exposed RCC terraces in Gurugram, Noida or industrial belts around Delhi routinely push slab surface temperatures well past 60°C in peak summer, and that heat radiates straight into the top floor — driving up AC bills and, over years, thermally cycling the waterproofing membrane underneath until it cracks. A 30 mm Foamshield layer with a conductivity of 0.023 W/mK meaningfully slows that heat transfer while simultaneously sealing the roof, which is why it shows up most often on IT park terraces, warehouse and PEB roofs, cold storage shells (where the insulation job is the primary one) and insulated tank farms — projects where a specifier is buying thermal performance and waterproofing in the same line item, applied by a trained crew like Space Arc’s rather than general site labour.

The technical insight

Foamshield’s chemistry is a standard rigid-PUF reaction — polymeric MDI (isocyanate) reacting with a polyol-based activator blend — but the numbers that matter on site are the reaction times and the density spread. Cream time of 5-10 seconds and tack-free time of 15-20 seconds (Pidilite’s internal test method) mean the applicator has almost no working window per pass, which is exactly why each spray is limited to a 10-15 mm rise and why machine calibration (mixing ratio held within ±2% by volume, hose temperature 40-45°C) is treated as non-negotiable in the method statement rather than a suggestion. In-place density of 45-50 kg/m³ against a free-rise density of 33-35 kg/m³ tells you the foam is meant to be sprayed against a surface, not poured freely — confinement and adhesion during expansion is what gets you the higher density and the >300 kPa compressive strength. The closed-cell content of >95% is what delivers both the low water absorption (<1.5% by volume) and most of the insulation value, since open cells would let convective air movement erode the R-value over time. One number specifiers sometimes gloss over: the B2 fire classification under DIN 4102, which is a “normal flammability” rating, not fire-retardant or non-combustible — it’s precisely why the TDS insists the foam can’t be left exposed beyond 24 hours and must be capped with a protective topcoat.

Where it is used

  • Thermal insulation-cum-waterproofing of exposed RCC terraces and flat roofs on commercial and institutional buildings
  • Podium deck insulation-waterproofing in mixed-use and residential township projects
  • Cold storage and cold-chain facility envelope insulation (walls and roof)
  • Pre-engineered building (PEB) and warehouse roof underside insulation
  • Insulation of water storage tanks and process/chemical tanks
  • Roof retrofit over old, failed membrane systems after strip-out and surface preparation
  • Sound and thermal insulation on institutional roofs (schools, hospitals, data centres) where cooling load matters
  • Large-format industrial and factory shed roofing where jointless coverage over long spans is critical

Key advantages

  • Seamless, jointless monolithic layer — no laps, joints or fasteners for water to exploit, unlike board insulation under a membrane
  • Very low thermal conductivity (0.023 W/mK) meaningfully cuts heat gain into the top floor or cold-store envelope
  • Fully bonded to the substrate, so there’s no lateral water migration path even if the topcoat is locally damaged
  • Lightweight (45-50 kg/m³) yet delivers >300 kPa compressive strength — negligible dead load on the structure
  • High wind uplift resistance because the foam is adhered, not mechanically fixed or loose-laid
  • CFC- and HCFC-free formulation, in line with green building and ozone-safety compliance
  • Fast, large-area coverage per shift once the crew and machine are mobilised, useful on big warehouse or PEB roofs
  • 90% of final strength reached within 4 hours of spraying, allowing the topcoat sequence to follow quickly

Limitations & considerations

  • Strictly a certified-applicator, machine-sprayed system — not something site labour or a homeowner can apply, and not sold as a retail DIY product
  • Must be protected with a UV-stable waterproof topcoat within 24 hours of spraying or the exposed foam discolours and degrades
  • Application window is weather-dependent: ambient/substrate temperature needs to sit between +20°C and +48°C, wind under 20 kmph, and humidity under 85% RH — monsoon and peak-winter scheduling both need care
  • B2 fire classification (DIN 4102) means the foam itself is normally flammable, not fire-retardant, so it always needs a protective covering and isn’t a bare finish for fire-sensitive zones
  • Two-component MDI/isocyanate chemistry requires PPE, trained handling and equipment that shouldn’t be mixed with other suppliers’ components
  • Minimum order quantities (250 kg / 210 kg drums, spray-rig mobilisation) make it economical only on sizeable roof areas, not small patch repairs

Selection & best practice

Get the base waterproofing layer right first — Foamshield goes over a cured Wonderproof 100, Superseal 4500 PUH or Superseal 500 GC coat on the mother concrete, not onto bare RCC, so that layer needs to be fully cured and the surface clean before spraying starts. Surface prep on the concrete itself should hit a CSP 2-3 profile via grinding or shot-blasting, with 50×50 mm angle fillets formed at every raft-wall or parapet junction before any spray begins. Always spray a 600×600 mm test patch at the start of the shift to confirm foam quality and machine settings before committing to the full roof. Build up thickness in 10-15 mm passes rather than trying to lay the full depth in one go, and don’t let any area sit exposed past 24 hours — sequence the crew so the protective topcoat follows close behind the foam spray, area by area, especially if rain or high humidity is forecast.

Specifications

Chemistry / system Two-component, polymeric MDI-based rigid polyurethane foam (CFC & HCFC free)
Density 45-50 kg/m³ (ASTM D1622)
Free rise density 33-35 kg/m³ (PITM)
Compressive strength > 300 kPa (ASTM D1621)
Tensile strength > 400 kPa (ASTM D1623)
Thermal conductivity (@ 24°C) 0.023 W/m·K (ASTM C518)
Water absorption (vol) < 1.5% (ASTM D2842)
Closed cell content > 95% (IS 11239 Part 5 / ASTM D6226)
Fire behaviour classification B2 (DIN 4102)
Standard IS 12432 – Part 3 (application)
Packaging Part A Activator: 250 kg drum; Part B Base: 210 kg drum

Industry use cases

Commercial / IT parks

Exposed RCC terrace insulation-cum-waterproofing on office campuses in Gurugram and Noida, where cutting top-floor heat gain directly reduces HVAC load.

Cold chain & logistics

Roof and wall envelope insulation for cold storage and cold-chain warehousing across the Delhi NCR logistics belt, where Foamshield’s jointless build limits thermal bridging.

Industrial / PEB sheds

Underside-of-roof spray insulation on pre-engineered warehouse and factory buildings to control condensation and radiant heat.

Mixed-use / residential townships

Podium deck insulation-waterproofing before landscaping or paver-block finishing, where a single fully bonded layer avoids future lateral leak tracking.

Utilities / process industry

Insulation of above-ground water storage and process tanks where evaporation loss and temperature stability matter.

Frequently asked questions

Can our own site team apply Foamshield, or does it have to be a certified applicator?
It has to be a certified, Pidilite-trained spray crew using calibrated plural-component equipment. The reaction times (foam goes tack-free in 15-20 seconds) leave no room for error, and the TDS itself specifies certified sprayers only — this isn’t a product regular site labour can apply.
Is Foamshield a waterproofing product or an insulation product?
Both, but sequentially. It’s sprayed over an already-cured waterproofing basecoat like Wonderproof 100 or Superseal 4500 PUH, and its own fully bonded, jointless nature adds a second line of defence against lateral water migration — but it’s specified primarily for its thermal insulation performance.
What happens if the sprayed foam is left exposed without a topcoat?
UV exposure discolours and degrades the foam surface within a day or two, and the manufacturer’s own guidance caps exposure at 24 hours before a protective waterproof topcoat must go on — this is a hard scheduling constraint on the job, not a suggestion.
Can Foamshield be used to retrofit an old, leaking terrace?
Yes, but the old membrane and any loose or friable material need to be stripped back to sound concrete first, the surface ground to the specified profile, and a fresh waterproofing basecoat applied and cured before foam spraying — it’s not a direct overlay on a failed roof.
Is this suitable for a small residential terrace?
Practically, no. The pack sizes (210-250 kg drums), spray-rig mobilisation and certified-crew requirement make it economical only on roof areas of a reasonable scale — most residential terraces are better served by Dr. Fixit’s membrane or coating-based waterproofing systems.
Is the foam fire-safe once installed?
On its own, Foamshield carries a B2 (normal flammability) rating under DIN 4102, not a fire-retardant rating, which is exactly why it’s always installed under a protective topcoat and shouldn’t be left as an exposed finish.

How we position Dr. Fixit Foamshield

Within the Dr. Fixit family, Foamshield is best understood as a companion product rather than a standalone one — it’s always specified on top of a cured basecoat such as Wonderproof 100, Superseal 4500 PUH or Superseal 500 GC, so any Foamshield scope of work on a Space Arc project effectively pulls in one of those systems as well. That two-layer logic is worth flagging to clients pricing the job: the quote isn’t just the foam spray, it’s the basecoat plus the foam plus the protective topcoat, executed as one sequenced system. There’s no genuinely equivalent single-system product from Fosroc in the Indian market today — Fosroc’s strength is in membrane and coating-based waterproofing (their Nitoproof and Proofex lines), and a specifier wanting rigid PU or PIR roof insulation alongside a Fosroc waterproofing membrane would typically need to bring in a separate specialist insulation contractor rather than get both from one manufacturer’s system, which is the gap Foamshield is built to close in a single scope.

Technical disclaimer. The technical information on this page is derived from Dr. Fixit’s published product literature and is provided by Space Arc Engineering as an authorised distributor for general guidance. Specifications can change; always confirm the current values against the manufacturer’s latest official Technical Data Sheet before specification or application. Source: Dr. Fixit official documentation.

Source Dr. Fixit Foamshield for your project

Authorised distribution, technical advice & professional application across Delhi NCR and Pan-India.