FOSROCAuthorised distributor

Fosroc Supercast PC

A water-only, shrinkage-compensated pile top fairing grout and structural void filler for pile cap reprofiling and restricted-access repairs.

BrandFosrocCategoryGrouts Structural RepairFormA ready-blended, cement-based, shrinkage-compensated grout supplied as a dry powder with selected aggregates that…

What is it?

A ready-blended, cement-based, shrinkage-compensated grout supplied as a dry powder with selected aggregates that needs only clean water on site to produce a highly fluid, self-flowing repair material. It is NOT a joint sealant or waterstop, despite sharing the Fosroc Supercast substructure-product name.

Where is it used?

Pile cap reprofiling (pile-top fairing), general structural void filling, and continuity repairs in foundations and substructures, typically below or near ground level on civil, infrastructure and building projects.

Why use it?

Delivers rapid early strength (25 N/mm2 at 1 day) and high ultimate strength (75 N/mm2 at 28 days) while compensating for shrinkage, so voids stay filled and load transfer is reliable without site vibration.

How is it applied?

Break out and prepare the repair area, erect rigid sealed formwork, pre-saturate or prime the substrate, mix one 25 kg bag with about 3 litres of clean water in a forced-action mixer for 3-5 minutes, then pour or pump the fluid grout into the void.

About Fosroc Supercast PC

Fosroc Supercast PC is a high-performance pile top fairing grout and cementitious void filler engineered for situations where structural continuity has to be re-established in foundations and substructures. It arrives on site as a factory-controlled blend of dry cements, additives and graded aggregates in a sealed bag. The applicator adds only clean water, which removes the batching guesswork that plagues site-mixed sand-cement and gives a consistent, repeatable repair every time. Once mixed, the material is fluid enough to flow into and around congested reinforcement and to fill the awkward, restricted pockets typical of pile-cap and void repairs, so it can be poured or pumped into place without mechanical vibration. A word on naming, because it matters for specifiers: Fosroc groups several unrelated substructure products under the Supercast banner, including PVC waterstops (Supercast PVC), hydrophilic strips (Supercast SW), and joint-and-injection accessories (Supercast EPT, Injectoseal). Supercast PC sits in none of those families. It is a structural grout, closer in purpose to the Conbextra and Renderoc repair ranges than to any sealant. If a drawing or BOQ calls for Supercast PC to seal a movement joint, that is almost certainly a specification error and should be queried before ordering. The product is shrinkage-compensated, meaning controlled positive expansion offsets the plastic and drying shrinkage that would otherwise leave a gap between the new grout and the surrounding concrete or steel; that intimate, void-free contact is exactly what makes load transfer dependable at a pile head. With rapid strength gain it suits programmes where formwork strike and follow-on work cannot wait, and it is placed in lifts of 15 to 250 mm. As an authorised Fosroc distributor and applicator, Space Arc Engineering supplies Supercast PC with the correct ancillaries (priming, formwork release and, where the water table is a factor, waterproofing protection) across Delhi NCR and Pan-India, together with the current region-specific TDS for project submittals.

The technical insight

The technical heart of Supercast PC is the combination of a very low water:powder ratio (0.12 by mass, roughly 3 litres of water to a 25 kg bag) with engineered flow and controlled expansion. A 0.12 ratio is far drier than a conventional flowable mortar, yet the material still self-levels because the flow comes from particle packing and admixtures rather than excess water. That low water demand is the reason for the strength profile: a dense, low-permeability matrix that reaches 25 N/mm2 compressive in 1 day, 45 N/mm2 at 7 days and 75 N/mm2 at 28 days (BS EN 196 Part 1), with flexural strength above 12 MPa at 28 days and water penetration under 10 mm (BS EN 12390 Part 8). Fresh wet density is about 2380 kg/m3, confirming a well-compacted, aggregate-loaded mix rather than a lightweight or foamed filler. The shrinkage compensation is the design pivot for void filling: in a sealed pile cap form, even a fraction of a millimetre of shrinkage would break contact at the top of the pour and undermine continuity, so the formulation is tuned to a small restrained expansion against the form and steel. Two practical consequences follow. First, the formwork must be genuinely rigid and grout-tight (silicone-sealed edges, internal faces treated with Reebol release agent so the form does not draw mixing water out of the grout) for the expansion to develop usefully. Second, free-fall drum mixers must not be used; the mix needs a forced-action pan mixer or a slow-speed drill (400-500 rpm) with a Fosroc paddle to fully activate the blend in 3-5 minutes. Below the water table, Supercast PC is specified alongside Supercast EPT and/or Proofex membranes so groundwater cannot compromise the cure or the surrounding structure.

Where it is used

  • Pile cap reprofiling and pile-top fairing, re-establishing a sound, level cap surface after pile trimming
  • General structural void filling where continuity of load path is required
  • Filling gaps and pockets between 15 mm and 250 mm thick in foundations and substructures
  • Pumped or poured repairs in congested, restricted-access locations without mechanical vibration
  • Soffit and bottom-up repairs where the form is filled from below with air-venting provision
  • Substructure and below-ground concrete reinstatement, used with Proofex/Supercast EPT protection at or below the water table
  • Infrastructure works (bridges, marine and civil foundations) needing rapid early strength for fast programme turnaround

Key advantages

  • Just add water on site – a factory-blended powder removes batching error and gives consistent, repeatable repairs
  • Rapid early strength of 25 N/mm2 at 1 day allows fast formwork strike and follow-on work
  • High ultimate strength of 75 N/mm2 at 28 days suits structural, load-transferring repairs
  • Shrinkage compensated, so the grout stays in intimate, void-free contact with concrete and reinforcement
  • Highly fluid and self-flowing – placed by pour or pump without vibration, ideal for congested or restricted areas
  • Low permeability (water penetration under 10 mm to BS EN 12390-8) for durable substructure repairs
  • Wide placement range of 15-250 mm per lift covers most pile-cap and void geometries
  • Backed by published BS EN test data and region-specific datasheets for specification and QA submittals

Limitations & considerations

  • NOT a joint sealant, waterstop or movement-joint product despite the Supercast brand name – has zero movement accommodation and must never be used to seal expansion or contraction joints
  • Cementitious and rigid, so it cannot tolerate ongoing structural movement or cyclic joint displacement
  • Requires rigid, grout-tight, release-treated formwork; poor formwork causes grout loss and lost shrinkage compensation
  • Free-fall drum mixers are unsuitable – a forced-action mixer or slow-speed drill with paddle is mandatory
  • Strict water dosage (about 3 litres per 25 kg bag, w:p 0.12); over-watering destroys strength and the no-vibration flow behaviour
  • At or below the water table it must be paired with Supercast EPT and/or Proofex membranes – it is not a standalone waterproofing system
  • Substrate must be saturated-surface-dry or primed with Nitobond EP; placing onto a dry or contaminated surface compromises bond
  • Like all cementitious repairs, it needs proper curing and is sensitive to very hot, windy Indian site conditions during placement

Selection & best practice

Treat Supercast PC strictly as a structural grout, never a sealant. Prepare the repair by saw-cutting the perimeter to at least 15 mm to avoid feather-edging and break out to a minimum 15 mm depth up to the square edge; remove all laitance, dust, oil and grease (steam clean or degrease) and verify cleanliness with a pull-off test. Fully expose and clean any corroded steel to a bright condition, including the back of bars. Erect rigid formwork tight to the substrate, seal the edges with silicone to stop grout loss, and treat the internal faces with Reebol release agent so the form does not absorb mixing water; include drainage for pre-soaking and air-vents for bottom-up pours. Pre-saturate the substrate for several hours and remove free water immediately before placing, or prime with Nitobond EP epoxy bonding agent. Always add powder to water – about 3 litres of clean, cool water per 25 kg bag – and mix 3-5 minutes in a forced-action mixer or with a 400-500 rpm drill and Fosroc paddle to a smooth, even consistency. Place promptly in lifts of 15-250 mm, and protect and cure per the current Fosroc TDS. At or below the water table, design it in with Supercast EPT and/or Proofex membranes, and always confirm values against the latest region-specific datasheet before submittal.

Specifications

Product typeShrinkage-compensated cementitious pile top fairing grout / void filler (NOT a sealant or waterstop)
Form suppliedReady-to-use dry powder blend with selected aggregates; just add water
Pack size25 kg bag
Mixing waterApprox. 3 litres clean water per 25 kg bag (water:powder ratio 0.12)
Placement thickness15 mm to 250 mm per lift (greater possible per configuration)
Compressive strength (BS EN 196-1)25 N/mm2 at 1 day; 45 N/mm2 at 7 days; 75 N/mm2 at 28 days
Flexural strength (BS EN 196-1)> 12 MPa at 28 days
Permeability / water penetration (BS EN 12390-8)< 10 mm
Fresh wet density2380 kg/m3
Mixing equipmentForced-action mixer or slow-speed drill (400-500 rpm) with Fosroc paddle; free-fall mixers not suitable
Substrate primingSaturate with clean water (SSD) or prime with Nitobond EP epoxy bonding agent
Formwork releaseReebol release agent; silicone-seal form edges
Below water tableUse with Supercast EPT and/or Proofex membranes
Movement accommodationNone – rigid grout; not for movement or expansion joints

Industry use cases

Piling & foundation contractors

Reprofiling and fairing pile tops after trimming to restore a level, sound cap surface that transfers load reliably, with 1-day strength allowing the cap pour to follow quickly.

Infrastructure & bridges

Filling structural voids and reinstating continuity in foundations, pier bases and abutments where rapid early strength keeps a tight construction programme moving.

Marine & water-retaining substructures

Void filling in below-ground and near-water elements, specified together with Proofex membranes or Supercast EPT where groundwater is present at or below the water table.

Industrial & building repair

Pumped or poured filling of congested, restricted-access pockets and soffit repairs without vibration, where site-mixed mortar would be inconsistent or impossible to compact.

Repair & rehabilitation specialists

Structural reinstatement of deteriorated foundation concrete around exposed, cleaned reinforcement, using the shrinkage-compensated grout for void-free, durable contact.

Frequently asked questions

Is Fosroc Supercast PC a joint sealant or waterstop?
No. Despite the Supercast brand name (which Fosroc also uses for PVC and hydrophilic waterstops and joint accessories), Supercast PC is a shrinkage-compensated cementitious grout for pile cap reprofiling and structural void filling. It has no movement accommodation and must never be used to seal expansion or movement joints. For those, use a Fosroc sealant such as Nitoseal, Thioflex or Colpor.
What is Supercast PC actually used for?
It is a high-performance pile top fairing grout and general structural void filler, used where structural continuity must be re-established – principally pile cap reprofiling and filling voids in foundations and substructures, placed in lifts of 15 to 250 mm.
How much water does a 25 kg bag need?
Approximately 3 litres of clean, cool water per 25 kg bag, giving a water:powder ratio of about 0.12. Always add the powder to the water and mix for 3-5 minutes. Over-watering severely reduces strength and ruins the self-flow behaviour.
What strength does Supercast PC achieve?
To BS EN 196-1 it develops about 25 N/mm2 compressive strength at 1 day, 45 N/mm2 at 7 days and 75 N/mm2 at 28 days, with flexural strength above 12 MPa at 28 days and water penetration under 10 mm to BS EN 12390-8.
Can it be used below the water table?
Yes, but not on its own. In conditions at or below the water table, Fosroc specifies Supercast PC in conjunction with Supercast EPT and/or Proofex membranes. Consult the local Fosroc office, or Space Arc Engineering, for the correct system build-up.
Can I mix it in an ordinary drum mixer?
No. Free-fall drum mixers are not suitable. Use a forced-action pan mixer, or a mixing vessel with a slow-speed drill at 400-500 rpm fitted with a Fosroc mixing paddle, to fully activate the blend to a smooth, even consistency.

How we position Fosroc Supercast PC

Within the Fosroc range, Supercast PC is a specialised pile-top and void-filling grout, not a sealant – a distinction that matters because the Supercast name is shared with genuine joint products. If your scope is movement-joint sealing, the correct Fosroc choices are the polyurethane/polysulphide gun-grade sealants Nitoseal and Thioflex, or the heavy-duty trafficked-joint sealant Colpor, and credible alternatives include Sika Sikaflex, MBCC/Master Builders Solutions MasterSeal and STP (Choksey) sealants. For the work Supercast PC is built for – pile cap reprofiling and structural void filling – it sits alongside Fosroc’s broader repair and grouting family: the Conbextra cementitious and epoxy grouts for precision and high-flow grouting, and Renderoc for hand- and spray-applied concrete repair, with Nitobond EP as the bonding primer and Proofex/Supercast EPT for below-water-table protection. Comparable structural grouts from other manufacturers include Sika’s SikaGrout range, Master Builders Solutions MasterFlow, and BASF/MBCC and Choksey grouting compounds widely available in India. As an authorised Fosroc distributor and applicator covering Delhi NCR and Pan-India, Space Arc Engineering can supply Supercast PC with the right ancillaries and the current region-specific datasheet, or steer you to the correct sealant or grout if Supercast PC is not in fact what your specification needs.

Technical disclaimer. The technical information on this page is derived from Fosroc’s published product literature and is provided by Space Arc Engineering as an authorised distributor for general guidance. Specifications can change; always confirm the current values against the manufacturer’s latest official Technical Data Sheet before specification or application. Source: Fosroc official documentation.

Source Fosroc Supercast PC for your project

Authorised distribution, technical advice & professional application across Delhi NCR and Pan-India.


Scroll to Top