MC-Bauchemie Samafit VK
A two-component chemical DPC injection that turns thirsty capillaries hydrophobic and stops rising dampness at its source — no strip-outs, no re-laying brick courses.
What is it?
A two-pack, ready-to-use liquid damp-proofing course from MC-Bauchemie, poured or pressure-injected into a row of pre-drilled holes along the base of a masonry wall to create a chemical barrier against rising dampness.
Where is it used?
Brick and stone masonry superstructures, heritage buildings and monuments, ground-floor walls in high-water-table pockets, and splash zones exposed to driving monsoon rain or flowerbed seepage.
Why use it?
The two components react inside the wall’s capillaries to form a gel that lines them and turns them water-repellent, stopping capillary rise for good — without breaking open the wall or re-laying a physical DPC.
How is it applied?
Holes are drilled in a zigzag pattern near the wall base; Samafit VK1 is poured in first and left to absorb, VK2 (or VK3 for stubborn cases) follows 30-60 minutes later, and the holes are then plugged with MC-Fix-ST before replastering.
About MC-Bauchemie Samafit VK
{“name”:”Samafit VK”,”slug”:”mc-samafit-vk”,”brand”:”MC-Bauchemie”,”realProduct”:”yes”,”officialSource”:”https://www.mc-bauchemie.in/products/waterproofing/dpc-injections/samafit-vk.html”,”category”:”waterproofing”,”metaTitle”:”Samafit VK | Stop Rising Damp | Space Arc”,”metaDescription”:”Samafit VK is MC-Bauchemie’s two-component chemical DPC injection that stops rising dampness in masonry walls, ideal for heritage and older structures.”,”heroSubtitle”:”A two-component chemical DPC injection that turns thirsty capillaries hydrophobic and stops rising dampness at its source — no strip-outs, no re-laying brick courses.”,”glance”:{“whatIsIt”:”A two-pack, ready-to-use liquid damp-proofing course from MC-Bauchemie, poured or pressure-injected into a row of pre-drilled holes along the base of a masonry wall to create a chemical barrier against rising dampness.”,”whereUsed”:”Brick and stone masonry superstructures, heritage buildings and monuments, ground-floor walls in high-water-table pockets, and splash zones exposed to driving monsoon rain or flowerbed seepage.”,”whyUse”:”The two components react inside the wall’s capillaries to form a gel that lines them and turns them water-repellent, stopping capillary rise for good — without breaking open the wall or re-laying a physical DPC.”,”howApplied”:”Holes are drilled in a zigzag pattern near the wall base; Samafit VK1 is poured in first and left to absorb, VK2 (or VK3 for stubborn cases) follows 30-60 minutes later, and the holes are then plugged with MC-Fix-ST before replastering.”},”about”:”Rising dampness is one of the most common — and most misdiagnosed — problems in older Indian masonry. A missing, cracked, or bridged Damp Proof Course lets ground moisture climb up brick and stone walls by capillary action, carrying dissolved salts with it. The visible symptoms follow a predictable script: paint bubbles and peels, plaster blisters and drums, skirting timber rots, and a tide-mark of efflorescence creeps up the wall regardless of how many coats of waterproof paint go on top. Because the moisture source is inside the capillary structure of the masonry itself, surface treatments rarely hold for long — the wall keeps wicking water from below.\n\nSamafit VK is MC-Bauchemie’s answer to exactly this problem, and it works from inside the wall rather than on its surface. It is a remedial, chemical alternative to physically cutting a new DPC course into an existing wall — a job that is disruptive, structurally risky on load-bearing or heritage masonry, and often impractical on monuments and old structures built with unconventional materials. Instead, a row of angled holes is drilled at the lowest practical point on the wall, and the two liquid components are introduced separately so they react and gel inside the capillaries themselves. Space Arc supplies and applies Samafit VK as part of MC-Bauchemie’s damp-proofing system for Delhi NCR clients, usually alongside MC-Fix-ST for plugging the drilled holes and, where surfaces are still wet at the time of treatment, Dichtament DS for surface-level waterproofing.”,”technicalInsight”:”The mechanism at work is often called silicification: the two Samafit VK components are formulated to stay unreactive on their own, but when introduced into the same capillary network in sequence, they combine and precipitate a gel that coats the internal pore walls. That gel does two things — it partially occludes the finest capillaries and, more importantly, it changes the wettability of the pore surface from hydrophilic (water-attracting) to hydrophobic (water-repelling). Capillary rise depends on water \”wetting\” the pore wall; once the wall is rendered non-wettable, the physics that pulls groundwater upward against gravity simply stops working. This is a different approach from cementitious crystalline waterproofing (which blocks pores mechanically) or surface DPC creams (which sit near the surface) — Samafit VK is designed to travel with the absorption front and react deep inside the masonry, which is why the drilling pattern, hole depth, and absorption time in the method statement matter as much as the material itself.”,”applications”:[“Retrofitting rising-damp control in older masonry residences, independent houses, and heritage bungalows across Delhi NCR”,”Ground-floor and plinth-level walls in buildings where the original DPC has failed, was bridged, or was never installed”,”Boundary and compound walls adjoining flowerbeds, lawns, or landscaped beds where soil stays in continuous contact with masonry”,”Structures in high-water-table pockets — riverside colonies, low-lying plots, and older South and East Delhi neighbourhoods”,”Splash-zone protection at the base of external walls repeatedly wetted by monsoon driving rain”,”Heritage and monument conservation work where cutting a physical DPC into the masonry is not an option”,”Godowns, warehouses, and industrial masonry walls showing salt efflorescence and peeling plaster from ground moisture”,”Pre-plastering and pre-painting remedial prep on damp-affected walls before a repaint or replaster cycle”],”advantages”:[“Non-invasive — no need to break open courses or cut a physical DPC into a load-bearing or heritage wall”,”Suited to brick, stone, and unconventional heritage masonry, not just modern block construction”,”Simple hand-tool application (masonry drill, spouted can, funnel or drip bottle) — no specialised injection pump needed for absorbent walls”,”Reacts in place to form a gel lining rather than a temporary surface coating, so the treatment stays where it’s needed”,”Cuts down the moss, fungus growth, timber decay, and salt efflorescence that come with chronic rising damp”,”12-month shelf life and a transparent-to-light-brown liquid that leaves no visible residue on the finished wall”,”Space Arc’s applicator team handles hole-spacing, dosing, and the VK1/VK2 sequencing on site rather than leaving it to guesswork”,”Slots into a complete MC-Bauchemie damp-proofing package with MC-Fix-ST for hole-plugging and Dichtament DS or Nisiwa SH where surface waterproofing is also needed”],”limitations”:[“A remedial treatment for existing rising dampness — it is not a substitute for installing a proper physical DPC during new construction”,”Performance depends heavily on wall porosity; very dense, glazed, or heavily painted masonry absorbs poorly and may need pressure injection or a different system altogether”,”Walls with hidden cavities, cracks, or voids connecting the drilled holes can drain the material away before the capillaries are saturated — the TDS explicitly calls for a water test before injection”,”Results aren’t instant: treated walls need roughly 2-3 weeks to dry out, and old damp plaster and paint must be stripped (they still hold salts) before replastering”,”Not a fix for hydrostatic or pressure-driven water ingress below grade — that calls for a membrane system such as Dichtament DS, not a capillary DPC injection”,”The manufacturer datasheet doesn’t publish independent lab figures for capillary water-absorption reduction, so performance is judged on site trial and applicator experience rather than a headline test number — worth a trial hole on unfamiliar substrates”],”bestPractice”:”Drill at the lowest practical point on the wall, close to where the original DPC line should sit, in a zigzag pattern — roughly 30 cm horizontal spacing and 15-20 cm vertical spacing, tightened up on denser, lower-absorption substrates. Angle holes at about 30°, to 70-90% of the wall thickness, with a 12-20 mm diameter; on walls thicker than 50 cm, drill from both faces so the material reaches every capillary. Always run a water test first to rule out hidden cavities or cracks that would just drain the product away. Pour Samafit VK1 first and let it absorb until uptake slows and the level holds steady; follow up 30-60 minutes (never more than an hour) later with VK2, or VK3 for stubborn dampness, repeating the full cycle the next day if the wall keeps drinking it in. Plug the holes with MC-Fix-ST, then strip all old damp plaster and paint, let the wall dry for 2-3 weeks, and only then apply a fresh waterproof plaster — replastering over salt-laden old plaster undoes the treatment.”,”specs”:[{“property”:”Product type”,”value”:”Two-component chemical damp-proofing course (DPC) for rising dampness”},{“property”:”Form / colour”,”value”:”Liquid, transparent to light brown”},{“property”:”Consumption”,”value”:”Approx. 200 g per hole for a 25 cm thick wall (varies with substrate absorption)”},{“property”:”Hole diameter”,”value”:”12-20 mm”},{“property”:”Hole inclination”,”value”:”30°”},{“property”:”Hole depth”,”value”:”70-90% of wall thickness”},{“property”:”Hole spacing”,”value”:”~30 cm horizontal, 15-20 cm vertical, zigzag pattern”},{“property”:”Shelf life”,”value”:”12 months from date of manufacture”},{“property”:”Pack sizes”,”value”:”30 kg container and 1 kg bottles”}],”useCases”:[{“sector”:”Heritage & Conservation”,”detail”:”Arresting rising damp in old havelis, colonial-era bungalows, and protected structures where cutting a physical DPC into the masonry isn’t permitted.”},{“sector”:”Residential Retrofit”,”detail”:”Ground-floor rooms of independent houses in Delhi NCR with peeling paint, blistered plaster, and a visible damp tide-mark from a failed or absent DPC.”},{“sector”:”Industrial & Warehousing”,”detail”:”Godown and warehouse boundary walls showing salt efflorescence and crumbling plaster from long-term ground moisture contact.”},{“sector”:”Institutional Buildings”,”detail”:”Schools, offices, and campus boundary walls built decades ago on old-style masonry, now needing non-disruptive damp remediation.”},{“sector”:”Landscape-Adjacent Structures”,”detail”:”Compound and garden walls next to flowerbeds or lawns, where continuous soil moisture keeps wicking up into the masonry.”}],”faq”:[{“q”:”How is Samafit VK different from a waterproof paint or damp-proof coating on the wall surface?”,”a”:”Surface coatings sit on top of the wall and stop working once the coating wears or the moisture pressure from below overcomes it. Samafit VK is injected into the wall itself and reacts inside the capillaries to make them permanently water-repellent, so it addresses the source of the rise rather than masking it at the surface.”},{“q”:”Can Samafit VK be used on RCC or concrete walls?”,”a”:”It’s designed for masonry — brick, stone, and similar porous construction materials — where rising damp travels through a network of fine capillaries. Dense RCC has a different pore structure and is usually not the right substrate for this treatment; talk to Space Arc’s team about the right MC-Bauchemie system if concrete is involved.”},{“q”:”How soon will we see the wall dry out after treatment?”,”a”:”Don’t expect an overnight change. The TDS calls for 2-3 weeks of drying time after treatment, and old damp plaster and paint need to be stripped first since they still hold salts that keep pulling in humidity — replastering too early undermines the result.”},{“q”:”Does application need special injection pumps?”,”a”:”Not usually. On absorbent masonry, Samafit VK1 and VK2/VK3 are simply poured into the drilled holes with a spouted can, funnel, or drip bottle and left to soak in. Pressure injection is only needed on denser, less absorbent masonry where gravity feed alone won’t saturate the capillaries.”},{“q”:”What’s the difference between Samafit VK2 and Samafit VK3?”,”a”:”VK2 is the standard second component paired with VK1 for routine rising-damp treatment. VK3 is a special-application grade of the second component, available on request for more stubborn or persistent dampness cases.”},{“q”:”Can Space Arc supply and apply Samafit VK in Delhi NCR?”,”a”:”Yes — as an authorised MC-Bauchemie distributor and applicator, Space Arc supplies Samafit VK in 30 kg containers or 1 kg bottles and can carry out the drilling and injection work itself, including the hole-spacing survey needed to price the job accurately.”}],”positioning”:”Samafit VK is the injection-based half of MC-Bauchemie’s rising-damp system in India; on site it’s almost always specified alongside MC-Fix-ST (for plugging the drilled holes) and, where the wall is still visibly wet, Dichtament DS for surface-level waterproofing or Nisiwa SH as an external water-repellent finish coat — Space Arc can package all three for a single damp-remediation job. Within the broader Indian construction-chemicals market, Fosroc’s mainstream catalogue doesn’t carry a direct, manufacturer-backed equivalent to a two-component gel-forming capillary DPC injection like Samafit VK; the nearest comparable approach tends to come from specialist silicone or siloxane-based DPC injection creams sold by regional damp-proofing contractors rather than a major multinational brand. For a project team that wants a documented system, applicator support, and a single point of accountability from drilling pattern through to replastering, Samafit VK backed by Space Arc’s MC-Bauchemie applicator team remains the straightforward choice.”}
The technical insight
The mechanism at work is often called silicification: the two Samafit VK components are formulated to stay unreactive on their own, but when introduced into the same capillary network in sequence, they combine and precipitate a gel that coats the internal pore walls. That gel does two things — it partially occludes the finest capillaries and, more importantly, it changes the wettability of the pore surface from hydrophilic (water-attracting) to hydrophobic (water-repelling). Capillary rise depends on water “wetting” the pore wall; once the wall is rendered non-wettable, the physics that pulls groundwater upward against gravity simply stops working. This is a different approach from cementitious crystalline waterproofing (which blocks pores mechanically) or surface DPC creams (which sit near the surface) — Samafit VK is designed to travel with the absorption front and react deep inside the masonry, which is why the drilling pattern, hole depth, and absorption time in the method statement matter as much as the material itself.
Where it is used
- Retrofitting rising-damp control in older masonry residences, independent houses, and heritage bungalows across Delhi NCR
- Ground-floor and plinth-level walls in buildings where the original DPC has failed, was bridged, or was never installed
- Boundary and compound walls adjoining flowerbeds, lawns, or landscaped beds where soil stays in continuous contact with masonry
- Structures in high-water-table pockets — riverside colonies, low-lying plots, and older South and East Delhi neighbourhoods
- Splash-zone protection at the base of external walls repeatedly wetted by monsoon driving rain
- Heritage and monument conservation work where cutting a physical DPC into the masonry is not an option
- Godowns, warehouses, and industrial masonry walls showing salt efflorescence and peeling plaster from ground moisture
- Pre-plastering and pre-painting remedial prep on damp-affected walls before a repaint or replaster cycle
Key advantages
- Non-invasive — no need to break open courses or cut a physical DPC into a load-bearing or heritage wall
- Suited to brick, stone, and unconventional heritage masonry, not just modern block construction
- Simple hand-tool application (masonry drill, spouted can, funnel or drip bottle) — no specialised injection pump needed for absorbent walls
- Reacts in place to form a gel lining rather than a temporary surface coating, so the treatment stays where it’s needed
- Cuts down the moss, fungus growth, timber decay, and salt efflorescence that come with chronic rising damp
- 12-month shelf life and a transparent-to-light-brown liquid that leaves no visible residue on the finished wall
- Space Arc’s applicator team handles hole-spacing, dosing, and the VK1/VK2 sequencing on site rather than leaving it to guesswork
- Slots into a complete MC-Bauchemie damp-proofing package with MC-Fix-ST for hole-plugging and Dichtament DS or Nisiwa SH where surface waterproofing is also needed
Limitations & considerations
- A remedial treatment for existing rising dampness — it is not a substitute for installing a proper physical DPC during new construction
- Performance depends heavily on wall porosity; very dense, glazed, or heavily painted masonry absorbs poorly and may need pressure injection or a different system altogether
- Walls with hidden cavities, cracks, or voids connecting the drilled holes can drain the material away before the capillaries are saturated — the TDS explicitly calls for a water test before injection
- Results aren’t instant: treated walls need roughly 2-3 weeks to dry out, and old damp plaster and paint must be stripped (they still hold salts) before replastering
- Not a fix for hydrostatic or pressure-driven water ingress below grade — that calls for a membrane system such as Dichtament DS, not a capillary DPC injection
- The manufacturer datasheet doesn’t publish independent lab figures for capillary water-absorption reduction, so performance is judged on site trial and applicator experience rather than a headline test number — worth a trial hole on unfamiliar substrates
Selection & best practice
Drill at the lowest practical point on the wall, close to where the original DPC line should sit, in a zigzag pattern — roughly 30 cm horizontal spacing and 15-20 cm vertical spacing, tightened up on denser, lower-absorption substrates. Angle holes at about 30°, to 70-90% of the wall thickness, with a 12-20 mm diameter; on walls thicker than 50 cm, drill from both faces so the material reaches every capillary. Always run a water test first to rule out hidden cavities or cracks that would just drain the product away. Pour Samafit VK1 first and let it absorb until uptake slows and the level holds steady; follow up 30-60 minutes (never more than an hour) later with VK2, or VK3 for stubborn dampness, repeating the full cycle the next day if the wall keeps drinking it in. Plug the holes with MC-Fix-ST, then strip all old damp plaster and paint, let the wall dry for 2-3 weeks, and only then apply a fresh waterproof plaster — replastering over salt-laden old plaster undoes the treatment.
Specifications
| Product type | Two-component chemical damp-proofing course (DPC) for rising dampness |
| Form / colour | Liquid, transparent to light brown |
| Consumption | Approx. 200 g per hole for a 25 cm thick wall (varies with substrate absorption) |
| Hole diameter | 12-20 mm |
| Hole inclination | 30° |
| Hole depth | 70-90% of wall thickness |
| Hole spacing | ~30 cm horizontal, 15-20 cm vertical, zigzag pattern |
| Shelf life | 12 months from date of manufacture |
| Pack sizes | 30 kg container and 1 kg bottles |
Industry use cases
Heritage & Conservation
Arresting rising damp in old havelis, colonial-era bungalows, and protected structures where cutting a physical DPC into the masonry isn’t permitted.
Residential Retrofit
Ground-floor rooms of independent houses in Delhi NCR with peeling paint, blistered plaster, and a visible damp tide-mark from a failed or absent DPC.
Industrial & Warehousing
Godown and warehouse boundary walls showing salt efflorescence and crumbling plaster from long-term ground moisture contact.
Institutional Buildings
Schools, offices, and campus boundary walls built decades ago on old-style masonry, now needing non-disruptive damp remediation.
Landscape-Adjacent Structures
Compound and garden walls next to flowerbeds or lawns, where continuous soil moisture keeps wicking up into the masonry.
Frequently asked questions
How is Samafit VK different from a waterproof paint or damp-proof coating on the wall surface?
Can Samafit VK be used on RCC or concrete walls?
How soon will we see the wall dry out after treatment?
Does application need special injection pumps?
What’s the difference between Samafit VK2 and Samafit VK3?
Can Space Arc supply and apply Samafit VK in Delhi NCR?
How we position MC-Bauchemie Samafit VK
Samafit VK is the injection-based half of MC-Bauchemie’s rising-damp system in India; on site it’s almost always specified alongside MC-Fix-ST (for plugging the drilled holes) and, where the wall is still visibly wet, Dichtament DS for surface-level waterproofing or Nisiwa SH as an external water-repellent finish coat — Space Arc can package all three for a single damp-remediation job. Within the broader Indian construction-chemicals market, Fosroc’s mainstream catalogue doesn’t carry a direct, manufacturer-backed equivalent to a two-component gel-forming capillary DPC injection like Samafit VK; the nearest comparable approach tends to come from specialist silicone or siloxane-based DPC injection creams sold by regional damp-proofing contractors rather than a major multinational brand. For a project team that wants a documented system, applicator support, and a single point of accountability from drilling pattern through to replastering, Samafit VK backed by Space Arc’s MC-Bauchemie applicator team remains the straightforward choice.
Related Waterproofing products
Source MC-Bauchemie Samafit VK for your project