Dr. Fixit Samshield PS 3500
A geotextile-toughened, self-adhesive SBS bitumen membrane built for basements, wet podiums and green roofs that can’t afford to leak.
What is it?
An SBS-modified bituminous membrane laminated onto tough geotextile fabric, self-adhesive on a peel-off release film, with a Preventol anti-root additive blended in.
Where is it used?
Basement raft slabs, retaining walls, lift pits and tanks; as a protection layer over other bitumen membranes and tapes; and under green roofs, terrace gardens, planters and wet podiums.
Why use it?
It pairs bitumen waterproofing with a geotextile face tough enough to survive backfill and site traffic, while the anti-root additive heads off roots piercing the membrane years later.
How is it applied?
Prime with Dr. Fixit Torchshield Primer, then peel, unroll and press the membrane from centre outward, rolling it firm; side laps use the built-in selvedge, end laps get Samshield Tape TS.
About Dr. Fixit Samshield PS 3500
Dr. Fixit Samshield PS 3500 (the manufacturer’s datasheet calls it Samshield PS 3500 AR) is an SBS-modified bituminous waterproofing and protection membrane. What sets it apart from a plain torch-applied sheet is the geotextile fabric the bitumen is laminated onto – that’s what gives it real puncture, chemical and UV resistance on a live site rather than just in a lab test. A Preventol anti-root additive is blended into the compound, letting specifiers use it under green roofs and planters without worrying about roots finding their way through later.
It earns its place on two lines of a BOQ. As a primary tanking system, it goes down on raft slabs and retaining walls in self-adhesive rolls, the 100 mm selvedge giving bitumen-to-bitumen contact at side laps while Samshield Tape TS closes the butt-jointed ends. As a protection layer, it’s laid over torch-applied sheets, coatings or tapes on walls and pipe penetrations, shielding the primary waterproofing before backfilling. Across Delhi NCR’s monsoon-exposed, high-water-table sites, that dual role – plus being a cold job rather than a torch one – usually decides it over a plain bitumen sheet.
The technical insight
The number worth flagging is 1304 N puncture resistance (ASTM E154) – well above a plain bitumen sheet, thanks to the geotextile lamination. It also holds a 5 bar (50 m head) hydrostatic test without leakage and a 110°C softening point (IS 1205), margins a deep basement actually needs. One detail that trips up site teams: the selvedge self-seals bitumen-to-bitumen, but the membrane’s own end laps are butt joints against polyester fleece that won’t bond to itself – hence Samshield Tape TS is mandatory there.
Where it is used
- Tanking of basement raft slabs and retaining walls below the water table
- Waterproofing of lift pits, sumps and underground water tanks
- Protection layer over torch-applied or self-adhesive bitumen membranes and tapes
- Root-resistant waterproofing under green roofs, terrace gardens and planters
- Wet podium decks in residential and commercial developments
- Damp-proofing course below slab-on-grade construction
- Puncture protection at pipe penetrations and complex profiles
Key advantages
- Geotextile lamination gives real puncture/tear resistance (1304 N, ASTM E154), surviving backfill and site traffic
- Cold, self-adhesive application – no torch or flame, useful on congested basement sites
- Preventol anti-root additive is a genuine differentiator for green-roof and podium work
- Tensile strength to 798 N/50mm and lap joint strength above 32 kg tolerate minor ground movement
- Bitumen-to-bitumen selvedge lap gives a continuous membrane, not a series of taped joints
- Holds a 5 bar (50 m) hydrostatic head without leakage – comfortable margin for deep basements
Limitations & considerations
- Needs Torchshield Primer and a clean, dry, cured substrate – skipping the primer is the top cause of poor bond on site
- End laps are butt joints (fleece won’t self-bond), so Samshield Tape TS is mandatory there – a step easy to value-engineer out
- It’s a black bituminous sheet, not a wearing surface – needs a protection board or screed before backfill or traffic
- The manufacturer flags 5-20% variation on quoted values, so critical projects should still ask for batch test certificates
- 18-month shelf life; rolls left uncovered through a Delhi summer degrade faster than storage assumptions allow
Selection & best practice
Start from the lowest point or floor drain so water runs over or parallel to the laps, never against them. Prime at 4-6 m²/litre and let it flash off before rolling membrane – rushing this is the top cause of blistering. Tape every butt-jointed end lap with Samshield Tape TS before the next roll goes down. Protect the laid membrane with a screed before backfilling, and pond water on basement slabs for 48-72 hours first – cheaper to find a pinhole now than dig up finished walls later.
Specifications
| Membrane type | SBS-modified bitumen laminated onto geotextile fabric, self-adhesive |
| Thickness | 3.5 mm |
| Weight (fibrous) | ~2952 g/m² |
| Elongation (L/T) | 47% / 54% (ASTM D 5147) |
| Tensile strength (L/T) | 798 / 571 N/50mm (ASTM D 5147) |
| Puncture resistance | 1304 N (ASTM E 154) |
| Peel adhesion strength | 10.5 kg (ASTM D 5147) |
| Softening point | 110°C (IS:1205) |
| Hydrostatic pressure resistance | 5 bar (50 m head), no leakage |
| Pack size | Roll 1 m x 10 m, approx. 30 kg |
Industry use cases
Residential high-rises, NCR
Raft slab and retaining wall tanking on shallow-water-table sites, where self-adhesive application avoided hot-works permits in an enclosed basement.
Commercial mall wet podiums
Applied beneath a landscaped podium with planters, anti-root additive specified to protect the tanking long-term.
Institutional/utility structures
Tanking lift pits and underground tanks where continuous bitumen-to-bitumen laps beat site-welded alternatives.
Villas and clubhouses with gardens
Specified under a rooftop garden for its root-repellent additive, avoiding root-puncture failures of ordinary membranes.
Frequently asked questions
Is Samshield PS 3500 the same as Samshield PS 3500 AR?
Do I need to prime the substrate first?
Can it be left exposed as a final terrace finish?
How is it different from a torch-applied membrane?
Do I need the anti-root version for a plain basement with no landscaping above?
How are end laps sealed if the selvedge is only on one side?
How we position Dr. Fixit Samshield PS 3500
Samshield PS 3500 belongs to Dr. Fixit’s below-grade family alongside Torchshield Primer (its required primer) and Samshield Tape TS (end-lap sealing) – specified together, not as substitutes. Where substrate repair is needed first, Dr. Fixit Pidicrete URP is the companion mortar on the same datasheet. Against Dr. Fixit’s torch-applied ranges, Samshield’s cold, self-adhesive format suits basements where an open flame isn’t practical. Outside the brand, Fosroc Proofex GP is the closest genuine equivalent – also self-adhesive bituminous tanking – worth considering where Fosroc is empanelled or anti-root isn’t needed; it lacks Samshield’s Preventol treatment, so for green roofs and planters, Samshield PS 3500 AR stays the more purpose-built pick. Space Arc supplies and applies both, so the call usually comes down to what’s on the BOQ.
Fosroc Proofex GP — For basement or retaining-wall tanking where the project is Fosroc-empanelled or doesn’t need root resistance, Proofex GP is a genuine self-adhesive bituminous alternative, though it lacks Samshield’s Preventol anti-root treatment for green-roof and podium work.
Related Waterproofing products
Source Dr. Fixit Samshield PS 3500 for your project
Authorised distribution, technical advice & professional application across Delhi NCR and Pan-India.