Normet TamCrete GP — General Purpose Class A Non-Shrink Cementitious Grout
An iron-free, chloride-free Class A grout that expands positively to lock in full contact under base plates, crane rails and anchor bolts — usable flowable or trowellable, and supplied for projects across Delhi NCR and Pan India by Space Arc.
What is it?
A factory-blended, non-shrink Class A cement-based grout that only needs clean water on site. It is built for critical grouting where positive expansion and a stain-free finish matter.
Where is it used?
Under stanchion bases, machine base plates and crane rails, for anchor bolts and masts, for pressure grouting, and as a dry-pack concrete repair material.
Why use it?
Positive expansion keeps the grout in full contact with the plate above, while rapid strength gain cuts downtime. No iron and no chlorides, so no rust staining and no risk to rebar.
How is it applied?
Mix a 25 kg bag with 5.2–5.6 litres of water for a flowable grout or 3.6–4.0 litres for a trowellable mix (at 30°C), then place it in one go.
About Normet TamCrete GP
Normet TamCrete GP (often searched as “Tamcrete GP”) is a general purpose, Class A, non-shrink cementitious grout. It comes pre-bagged, so the cement, graded filler and expansion system are proportioned in the factory and the site crew only adds water. That removes the most common grouting error on Indian sites — guesswork batching with loose cement, sand and an off-the-shelf expander.
The grout has one job: fill the gap between a load-bearing element and its support completely, and stay in contact for the life of the structure. TamCrete GP does this with positive expansion, high ultimate strength and low permeability. Space Arc Engineering, Pan India Project Distributor of NORMET, supplies TamCrete GP to contractors, fabricators and plant owners and supports the first pour with mix and placement guidance.
The technical insight
Ordinary cement-sand grout shrinks as it loses water and hydrates, leaving a hairline gap under the base plate. Load then travels only through high spots, and vibration slowly breaks the bedding apart. A Class A non-shrink grout is designed to counter this with controlled positive expansion. Normet’s TDS reports +1% expansion at 28 days for the flowable mix and a volume change of +1.5% to +2% at 28 days for the trowellable mix (ASTM C827). That small growth presses the grout up against the steel and keeps the load path continuous.
Two other details make TamCrete GP suitable near steel. It is iron-free, so there are no metallic particles to rust, expand and stain exposed faces. And it is chloride-free, so it can sit directly against reinforcement and holding-down bolts without feeding corrosion.
Where it is used
- Bedding grout under steel stanchion and column base plates
- Machine base plates for pumps, compressors and plant equipment
- Crane rail bedding in factories, yards and workshops
- Anchoring grout for anchor bolts, masts and poles
- Pressure grouting of voids and pockets
- Dry-pack concrete repair at low water content
- Pocket grouting for holding-down bolts in new foundations
- Re-grouting under equipment after alignment or replacement
Key advantages
- Positive expansion for full contact and support under the bearing element
- Usable in two consistencies: flowable or trowellable
- 28-day compressive strength of 50 MPa (flowable) and 65 MPa (trowellable) as per the TDS
- Rapid strength development keeps plant downtime short
- Factory-controlled blend removes site batching errors
- Low permeability and high ultimate strength for long-term durability
- Iron-free — no rust staining or rust expansion
- Chloride-free — safe in contact with reinforcing steel
Limitations & considerations
- Normet’s TDS does not publish a detailed placement method; it asks users to refer to the technical department, so plan the first pour with our team
- Warm mixing water shortens working time and reduces flow — important in North Indian summers
- Shelf life is six months in unopened bags; rotate stock and check bag dates
- Store between 10°C and 38°C, dry and out of direct sunlight
- Published values are laboratory results at 25°C; run a site trial to confirm performance
- Make an allowance for waste when estimating quantities from the yield figures
Selection & best practice
Choose the consistency to suit the job. The flowable mix (5.2–5.6 litres of water per 25 kg bag at 30°C) suits base plates and rail bedding where the grout has to travel under steel; the trowellable mix (3.6–4.0 litres) suits dry-pack repairs and pockets that are packed by hand. Never add water beyond the stated range to make the grout flow further — it weakens the grout and works against the expansion system.
In hot weather, keep bags in shade and use the coolest clean water available, because warm water reduces workability time and flow. Plan the pour so that the full volume can be placed without stopping. For estimating, Normet gives an approximate yield of 14 litres (flowable) or 12 litres (trowellable) per 25 kg bag, so a 100-litre void needs roughly 8 bags at flowable consistency, plus waste. Space Arc can review your detail and help set up a trial mix before the main pour.
Specifications
| Product type | Non-shrink, Class A, cement-based high-strength grout |
| Compressive strength @ 28 days – flowable | 50 MPa (CS1:1990 section 12 / ASTM C942) |
| Setting time – flowable | Initial > 1 hour; final < 10 hours (ASTM C953) |
| Expansion @ 28 days – flowable | +1% (GS:1992 clause 17.59–17.60 / ASTM C940) |
| Flow consistency – flowable | 10–30 seconds (ASTM C939) |
| Compressive strength @ 28 days – trowellable | 65 MPa (BS 4550) |
| Setting time – trowellable | Initial > 1 hour; final < 4 hours (BS 4550) |
| Flow consistency – trowellable | 30–45% (BS 4551) |
| Volume change @ 28 days – trowellable | +1.5% to +2% (ASTM C827) |
| Slant shear bond strength | > 2.0 MPa |
| Water per 25 kg bag (at 30°C) | Flowable 5.2–5.6 litres; trowellable 3.6–4.0 litres |
| Approximate yield per 25 kg | Flowable 14 litres; trowellable 12 litres |
| Packaging | 25 kg heavy-duty bag |
| Storage / shelf life | 10°C to 38°C, dry, out of direct sunlight; six months unopened |
Values as per Normet’s published TDS (Asia edition, V1ASIA18, 2018), tested at 25°C under laboratory conditions unless stated. Download the TDS for the full data sheet.
Industry use cases
Steel Structures & PEB Sheds
Base plate grouting for columns once the frame is aligned and the holding-down bolts are set.
Industrial Plants
Bedding of pumps, compressors, motors and other equipment where vibration would break down an ordinary sand-cement bed.
Material Handling & Cranes
Continuous bedding under crane rails so wheel loads spread evenly into the beam or slab.
Power & Utilities
Anchor bolt and mast grouting for poles, towers and outdoor equipment foundations.
Maintenance Teams
Dry-pack repair of broken edges and pockets around existing machine foundations.
Frequently asked questions
What is Normet TamCrete GP used for?
How much water do I add to a 25 kg bag of TamCrete GP?
How many bags of TamCrete GP do I need?
What strength does TamCrete GP reach?
Will TamCrete GP stain or harm the steel?
Is there a Normet TamCrete GP supplier in Delhi NCR?
How we position Normet TamCrete GP
TamCrete GP is our general recommendation for base plates, crane rails and anchor bolts where a reliable Class A non-shrink grout is needed. When the gap is narrow, the pour is long or the grout has to be pumped, we look at Normet TamCrete HF, the high-flow grout in the same family. For sealing actively leaking holes before grouting, Normet TamCrete Plug stops the water first.
For grout mixes that need a separate admixture, such as microfine cement injection or tunnel backfill grout, see TamCem 15, TamCem 8BFG and TamCem 9BFG. Browse the full Normet range for every product we supply.
More Normet grouting products
Source Normet TamCrete GP for your project
Pan India project supply from Space Arc, with technical support for trials, dosage and site work.