Normet TamCem 15 — Superplasticiser for Microfine Cement Injection Grouts
A chloride-free, sulphonated-polymer superplasticiser that disperses microfine cement grouts for deeper penetration into fine cracks and soils — dosed at 1.0–2.0% of binder and supplied for projects Pan India by Space Arc.
What is it?
A non-chloride liquid superplasticiser based on sulphonated polymers. It is made for microfine cementitious injection grouts and can also act as a mid-range superplasticiser in other concrete and grout mixes.
Where is it used?
Microfine cement injection for ground improvement, rock and soil grouting and crack sealing, and concrete or grout mixes that need more strength and workability.
Why use it?
High water reduction and better dispersion keep fine cement particles apart, so the grout penetrates further, stays cohesive and bleeds less at a lower water/cement ratio.
How is it applied?
Add 1.0–2.0% by weight of cementitious binder through a separate dispenser, into the mixing water or the mixed grout, and mix in a high-speed colloidal mixer at 1,500 rpm or more.
About Normet TamCem 15
Normet TamCem 15 (also written “Tamcem 15”) is a superplasticiser designed around one of the hardest jobs in grouting: getting cement into very fine openings. Microfine and ultrafine cements are ground much finer than ordinary cement so they can enter fine cracks and soil pores, but very fine particles clump together easily. Once clumped, they behave like coarser cement and block the very openings they were meant to fill.
TamCem 15 prevents that. It keeps the particles dispersed, cuts the water needed for a pumpable grout, and reduces bleed so the injected grout fills and seals rather than settling out. Space Arc Engineering, Pan India Project Distributor of NORMET, supplies TamCem 15 together with microfine cement systems and supports trials to set the right dosage for each ground or structure.
The technical insight
The sulphonated polymers in TamCem 15 adsorb onto cement particles and give them a like charge, so they repel each other instead of forming flocs. In a microfine grout, that dispersion is what controls penetration: a well-dispersed grout behaves according to its true particle size, while a flocculated one acts as if it were much coarser. Normet pairs this with mechanical dispersion — the TDS recommends a high-speed colloidal mixer at a minimum of 1,500 rpm when TamCem 15 is used with microfine cements such as TamCrete MFC or TamCrete UFC.
The second effect is water reduction. A lower water/cement ratio means less free water to bleed out of the grout after injection, better cohesion without segregation, and a denser, stronger set grout in the treated zone. With a chloride ion content below 0.01%, the admixture can also be used where the grout will be in contact with steel.
Where it is used
- Microfine cement injection grouting
- Ultrafine cement grouting of fine fissures and soils
- Ground improvement and water cut-off grouting
- Rock fissure and joint grouting in tunnels and foundations
- Crack injection with cementitious grout in structures
- Concrete and grout mixes needing more strength and workability
- Mid-range water reduction in general grouting
- Grouting mixes made with TamCrete MFC or TamCrete UFC
Key advantages
- Chloride-free (chloride ion content < 0.01%)
- Improves penetration of microfine cements such as TamCrete MFC and TamCrete UFC
- Improves workability of the grout or mix
- Allows a reduced water/cement ratio
- Good cohesion with no segregation and reduced bleed water
- Also usable as a mid-range superplasticiser in other mixes
- Liquid form, easy to dose through a dispenser
- One-year shelf life in sealed packaging
Limitations & considerations
- Do not use together with other manufacturers’ admixtures; check compatibility with other Normet admixtures first
- Do not add to a dry mix — add to the mixing water or the already mixed grout
- Trial mixes are needed to set the dosage for each job
- Needs a high-speed colloidal mixer (minimum 1,500 rpm) for full benefit with microfine cements
- Freezes at about −4°C; it recovers after thawing and gentle mechanical agitation
- Store above 0°C, dry and out of direct sunlight
Selection & best practice
Start trials at the middle of Normet’s typical range of 1.0–2.0% of cementitious binder content and adjust to the target flow, bleed and set for the grout. Use an independent dispenser and feed line so the dose is accurate batch after batch. Add TamCem 15 to the mixing water or to the mixed grout, never to the dry powder.
With microfine or ultrafine cements, mixing method matters as much as dosage. Use a high-speed colloidal mixer running at 1,500 rpm or more, and keep a record of mixing time, water/cement ratio and dosage during trials so the production grout matches what was approved. Space Arc can help plan the trial programme and supply the matching microfine cement.
Specifications
| Product type | Non-chloride superplasticiser based on sulphonated polymers |
| Form / colour | Liquid / dark brown |
| Relative density | 1.22 ± 0.03 g/cm³ |
| Solids content | 38.0 ± 2.0% |
| pH | 8.5 ± 1.0 |
| Chloride ion content | < 0.01% |
| Typical dosage | 1.0–2.0% of cementitious binder content |
| Mixing with microfine cement | High-speed colloidal mixer, minimum 1,500 rpm |
| Packaging | IBCs, drums and bulk |
| Storage / shelf life | Above 0°C, dry, out of direct sunlight; one year sealed. Freezes at about −4°C |
Values as per Normet’s published TDS (Global edition, V1WW16, 2016), measured at 20°C under laboratory conditions. Download the TDS for the full data sheet.
Industry use cases
Tunnelling & Underground Works
Microfine cement grouting of fissured rock to cut water ingress around tunnels and shafts.
Dams & Hydro Projects
Grout mixes for sealing fine joints and fissures in rock foundations.
Ground Engineering Contractors
Soil and rock injection where ordinary cement is too coarse to penetrate.
Structural Repair
Cementitious injection of fine cracks in concrete where a mineral, cement-based repair is preferred.
Grouting Specialists
Mid-range water reduction for general grouting mixes needing better flow and strength.
Frequently asked questions
What is Normet TamCem 15 used for?
What is the dosage of TamCem 15?
Which mixer should be used with TamCem 15?
Can TamCem 15 be mixed with other admixtures?
Is TamCem 15 the same as TamCem 15P?
Who supplies Normet TamCem 15 in India?
How we position Normet TamCem 15
TamCem 15 is the admixture we pair with microfine cement injection, using Normet TamCrete MFC / SFC or Normet TamCrete UFC as the binder. For tunnel backfill grouts behind TBM segments, the retarding plasticisers TamCem 8BFG and TamCem 9BFG are the better fit.
Where a pre-bagged grout is simpler than site-mixed grout plus admixture, TamCrete GP and TamCrete HF are ready to use with water. See the full Normet range for every product we supply.
More Normet grouting products
Source Normet TamCem 15 for your project
Pan India project supply from Space Arc, with technical support for trials, dosage and site work.