Normet TamCem 8BFG — Set-Retarding Plasticiser for TBM Backfill Grout and Concrete
A chloride-free plasticiser/retarder that gives TBM backfill grouts and concrete a long, controllable open time with high water reduction — EN 934-2 and ASTM C494 Type B as per Normet’s TDS, supplied Pan India by Space Arc.
What is it?
A non-chloride liquid plasticiser and set retarder for TBM backfill (annulus) grouts and selected concrete uses. It complies with EN 934-2 and ASTM C494 for Type B retarding admixtures.
Where is it used?
Two-component backfill grouts behind TBM segments, hot-weather concrete and grouting, large pours, temperature-controlled concrete and ready-mixed concrete travelling long distances.
Why use it?
It holds the grout or concrete workable for longer without bleed or segregation, so batching, transport and placement stay under control — then sets normally, or on demand when an accelerator is added.
How is it applied?
Dose 0.4–1.5% of cementitious binder through a separate dispenser into the mixing water or mixed material; in backfill grout, set is triggered with a sodium silicate accelerator.
About Normet TamCem 8BFG
Normet TamCem 8BFG (“Tamcem 8 BFG”) is a retarding plasticiser developed mainly for the backfill grout injected into the annular gap behind tunnel lining segments. That grout has to stay pumpable through a long supply line and a working shift, then gain strength quickly once it reaches the annulus. TamCem 8BFG supplies the first half of that balance: high water reduction and a long, controllable open time.
The same chemistry is useful above ground. Normet lists hot-weather concrete, peak-temperature-controlled concrete, large pours and long-distance transport of ready-mixed concrete among its uses. Space Arc Engineering, Pan India Project Distributor of NORMET, supplies TamCem 8BFG and supports grout and concrete trials to fix the right dosage for the cement, temperature and haul time on your project.
The technical insight
TamCem 8BFG works in two ways. As a plasticiser it disperses cement particles, giving high water reduction and greater workability; Normet notes this dispersion also improves strength. As a retarder it slows the hydration reaction, extending both initial and final set. Together these give a grout or concrete that stays cohesive, with minimal bleed and no segregation, for much longer than an untreated mix.
In a two-component TBM backfill grout, the retarded grout (component A) is kept fluid until it meets an accelerator at the injection point. Normet’s TDS states that setting and hydration can be regulated using sodium silicate accelerators such as TamShot 10SS. In concrete, the same retardation helps control peak temperature in mass pours and keeps workability during long trips from the batching plant.
Where it is used
- TBM backfill (annulus) grout behind tunnel segments
- Hot-weather concrete and grouting
- Peak-temperature-controlled concrete
- Large pours where mixing logistics need a long open time
- Ready-mixed concrete hauled over long distances
- High-performance and high-strength concrete
- Highly durable concrete
- Concrete and grout needing extended set time
Key advantages
- Long, controllable open time for better placement and delivery control
- High water reduction and greater workability
- Good cohesion, no segregation and minimal bleed even at very high workability
- Retards both initial and final set
- Set can be triggered with sodium silicate accelerators in backfill grout
- High elastic modulus and low shrinkage and creep with graded aggregates (per TDS)
- Superior surface finishes
- Chloride-free; complies with EN 934-2 and ASTM C494 Type B
Limitations & considerations
- Dosage must be fixed by trial mixes; over-dosing extends set time
- Do not use with other manufacturers’ admixtures; check compatibility with other Normet admixtures first
- Do not add to a dry mix
- Above 1.5% of binder, consult before use as the TDS advises
- Must not freeze; store in sealed stainless steel or plastic tanks at 5°C to 30°C
- Keep out of direct sunlight; shelf life one year under these conditions
Selection & best practice
Begin trials within Normet’s typical range of 0.4–1.5% of cementitious binder and measure what matters for the job: open time and pumpability for backfill grout, or slump retention and set time for concrete. Retardation depends on cement type, binder content and temperature, so repeat trials when any of these change, for example between winter and summer in North India.
Dose through an independent dispenser and feed line into the mixing water or the mixed material, never onto dry materials. For two-component backfill grout, test the full system — retarded grout plus accelerator — to confirm gel time and early strength before production. Space Arc can coordinate the trial and supply the matching Normet products.
Specifications
| Product type | Set-retarding, plasticising admixture (non-chloride) |
| Standards | EN 934-2; ASTM C494 Type B (retarding) |
| Form / colour | Liquid / brown |
| Density | 1.22 ± 0.03 g/cm³ |
| pH | 7.0 ± 1.0 |
| Chloride ion content | < 0.1% |
| Typical dosage | 0.4–1.5% of cementitious binder content |
| Packaging | IBCs, drums and bulk |
| Storage / shelf life | Sealed stainless steel or plastic tanks, 5°C to 30°C, no freezing, out of sunlight; one year |
Values as per Normet’s published TDS (Global edition, V1WW17, 2017), measured at 25°C under laboratory conditions. Download the TDS for the full data sheet.
Industry use cases
Metro & Tunnelling (TBM)
Component A of two-component backfill grout, kept fluid through long supply lines until accelerated at the segment.
Ready-Mixed Concrete
Slump retention for long hauls through city traffic, where concrete can lose workability before it reaches site.
Mass Concrete & Rafts
Retarded, temperature-controlled pours for raft foundations and thick sections.
Hot-Weather Concreting
Extended working time for concrete and grout placed in high summer temperatures.
Infrastructure Projects
High-strength, durable concrete where workability must hold during large continuous pours.
Frequently asked questions
What is TamCem 8BFG used for?
What is the dosage of TamCem 8BFG?
Which standard does TamCem 8BFG meet?
How is the set controlled in TBM backfill grout?
What is the difference between TamCem 8BFG and TamCem 9BFG?
Who supplies Normet TamCem 8BFG?
How we position Normet TamCem 8BFG
TamCem 8BFG is our standard choice for a retarded, two-component TBM backfill grout and for concrete that needs a long, reliable open time. When early strength of the accelerated grout is the main concern, we compare it with Normet TamCem 9BFG, which adds a dormant strength enhancer.
For microfine cement injection rather than backfill, TamCem 15 is the right admixture. To keep batching plants, agitators and grout pumps free of hardened build-up, TamCrete CR removes residue chemically. See the full Normet range for every product we supply.
More Normet grouting products
Source Normet TamCem 8BFG for your project
Pan India project supply from Space Arc, with technical support for trials, dosage and site work.