Fosroc Nitoflor Conductive

FOSROCAuthorised distributor

Fosroc Nitoflor Conductive

A 2 mm seamless epoxy static-conductive floor topping that safely bleeds static charge to earth — engineered for electronics, clean rooms, magazines and operating theatres where ESD control is non-negotiable.

BrandFosrocCategoryIndustrial FlooringFormA solvent-free epoxy-resin static-conductive (and dissipative) self-smoothing floor topping system that drains…

What is it?

A solvent-free epoxy-resin static-conductive (and dissipative) self-smoothing floor topping system that drains electrostatic charge to earth through an embedded conductive undercoat and copper earthing network, laid at 2 mm.

Where is it used?

Electronics manufacturing and assembly lines, clean rooms, computer/server rooms, defence and explosives magazines, pharmaceutical units, and hospital operating theatres across India.

Why use it?

It delivers a verified surface resistance of 5×10⁴–1×10⁶ ohms (CPRI-certified to BS 2050), preventing static build-up that can destroy electronic components or ignite flammable atmospheres, while giving a seamless, hygienic, chemical-resistant floor.

How is it applied?

Specialist-applied as a three-part system — Nitoprime 25 primer, a conductive undercoat tied to copper earthing strips, then a 2 mm trowel-and-spike-rolled conductive topcoat — over sound, dry (<5%) concrete.

About Fosroc Nitoflor Conductive

Fosroc Nitoflor Conductive is a static-control epoxy flooring system designed for environments where uncontrolled electrostatic discharge (ESD) is a genuine hazard — to sensitive electronic components, to product yields, or to people working around flammable vapours and dusts. In the Indian Fosroc range it is supplied as the Nitoflor SL Conductive / Dissipative system, a self-smoothing flow-applied topping built from blended epoxy resins, curing agents and graded inert aggregates. The conductive variant is engineered to hold a surface and bulk resistance of 5×10⁴ to 1×10⁶ ohms, while the companion dissipative grade sits higher at 1×10⁶ to 1×10⁹ ohms for areas needing slower, gentler charge bleed-off.\n\nWhat makes the system function is not a single coat but a deliberately layered build. A coat of Nitoprime 25 seals and bonds to the prepared substrate. Over that, a conductive undercoat — itself a low-resistance epoxy in the 3×10³–9×10³ ohm range — is rolled on at a tightly controlled coverage rate and tied into copper earthing connections placed at the floor edges and across every movement joint. Finally a 2 mm pigmented conductive topcoat is poured, trowelled and spike-rolled to a smooth, light-reflective, seamless finish. The earthing network and the undercoat together give static electricity a continuous, reliable path to ground; the topcoat carries the wear, chemical exposure and appearance. The completed floor is CPRI (Central Power Research Institute) certified for charge dissipation, which matters a great deal to Indian consultants writing specifications for defence, electronics and pharma clients.\n\nFor contractors, consultants and procurement teams in India, the appeal is a single accountable system that answers a hard performance question — measured resistance to earth — rather than a decorative coating that merely claims anti-static behaviour. Space Arc Engineering, as an authorised Fosroc distributor and applicator across Delhi NCR and Pan-India, supplies the full system together with the surface preparation, earthing layout and electrical verification that make the warranty meaningful.

The technical insight

The single most misunderstood point about conductive flooring is that the number on the datasheet is a system property, not a product property. Nitoflor Conductive’s headline 5×10⁴–1×10⁶ ohm rating (per BS 2050:1978 and DIN EN 1081) is only achieved when the conductive undercoat is applied at its specified consumption — 6.3 to 7.3 m²/litre — and is electrically bonded to a properly grounded copper earthing grid. Over-apply the undercoat, skip an earthing tie at a joint, or let coverage drift, and the resistance to earth climbs out of range, quietly defeating the whole installation. This is why the undercoat’s own resistance (3×10³–9×10³ ohms) must be physically measured on site before the topcoat goes down — the verification step is part of the method statement, not an optional extra. The system also carries a Federal Test Method 101B, Method 4046 static-decay claim of under 0.01 seconds to discharge a +5kV peak to 0%, the metric that genuinely protects ESD-sensitive electronics. Mechanically the topping is robust (50 N/mm² compressive, 16 N/mm² tensile, 34 N/mm² flexural per BS 6319), but its electrical performance is entirely application-dependent — making applicator competence the real specification.

Where it is used

  • ESD-safe flooring for electronics manufacturing, PCB assembly and semiconductor handling areas
  • Clean rooms and controlled environments in pharmaceutical and medical-device plants
  • Computer rooms, data centres and server halls requiring static dissipation
  • Defence and ordnance magazines, explosives and pyrotechnics stores with flammable-atmosphere risk
  • Hospital operating theatres and critical-care suites
  • Hazardous dust and solvent-handling process areas where static ignition is a risk

Key advantages

  • Verified static control — provides an effective, continuous passage of static electricity to earth, CPRI-certified to 5×10⁴–1×10⁶ ohms
  • Fast static decay — discharges a +5kV charge to 0% in under 0.01 seconds (FTM 101B Method 4046), protecting sensitive electronics
  • Seamless and hygienic — dense, impervious, jointless surface that is easy to clean and suits clean-room and theatre use
  • Chemically resistant — withstands petrol, oils and fats, detergents, some aliphatic hydrocarbons and dilute alkalis
  • Durable — good abrasion resistance with 50 N/mm² compressive strength for industrial traffic
  • Aesthetic flexibility — available in a range of colours and a light-reflective finish to improve working environments
  • Dual-grade family — conductive and dissipative versions let the specifier match the resistance band to the exact application

Limitations & considerations

  • Electrical performance is fully application-dependent — incorrect undercoat coverage or a missed earthing connection puts resistance out of range
  • Must not be applied below 15°C, which requires planning for winter installations in North India
  • Requires a sound, dry substrate — concrete at least 28 days old with moisture content below 5%, and a damp-proof membrane to prevent osmosis
  • At only 2 mm the topping is not self-levelling over major substrate defects; the slab must be relatively even and pre-repaired (e.g. with Nitomortar S)
  • Cannot be applied over asphalt, unmodified sand/cement screeds, PVC tiles or vinyl
  • Full chemical and traffic service requires curing — foot traffic after 24 hours and full traffic after 5 days at 30°C
  • Earthing layout, copper-strip placement and on-site resistance verification demand a trained specialist applicator, not a general painter

Selection & best practice

Treat the earthing design as the first deliverable, not an afterthought: agree copper-strip locations and joint bridging with Fosroc/Space Arc before priming, place earthing connections at floor perimeters and across every expansion/movement joint, and physically measure the conductive undercoat’s surface resistance (target 3×10³–9×10³ ohms) before laying the topcoat. Apply over a damp-proof-membrane-protected slab that is at least 28 days old and below 5% moisture, prime with Nitoprime 25 (two coats on porous floors), hold the undercoat to its exact 6.3–7.3 m²/litre rate, and spike-roll the 2 mm topcoat to release entrained air. Never apply below 15°C and always commission the finished floor with a documented resistance-to-earth test.

Specifications

Chemical type Blended epoxy resins, curing agents and graded inert aggregates (solvent-free, self-smoothing topping)
Surface resistance — Conductive 5 x 10⁴ – 1 x 10⁶ ohms (BS 2050:1978, DIN EN 1081)
Surface resistance — Dissipative 1 x 10⁶ – 1 x 10⁹ ohms (companion grade)
Conductive undercoat resistance 3 x 10³ – 9 x 10³ ohms (verified before topcoat)
Static decay +5kV peak to 0% in not more than 0.01 seconds (FTM 101B, Method 4046)
Applied thickness 2 mm (topcoat)
Flooring system 1 coat Nitoprime 25 + 1 conductive undercoat (with copper earthing) + 1 conductive topcoat
Compressive strength 50 N/mm² (BS 6319)
Tensile strength 16 N/mm² (BS 6319)
Flexural strength 34 N/mm² (BS 6319)
Specific gravity (mixed) Approx. 1.7
Volume solids 100%
Temperature resistance Up to 80°C (service)
Pot life Approx. 30 min at 30°C
Cure / overcoat Foot traffic after 24 hrs; full traffic after 5 days (at 30°C)
Coverage — undercoat 6.3 – 7.3 m²/litre (conductive); 6.7 – 7.8 m²/litre (dissipative)
Coverage — topcoat 7.5 m²/15-litre pack at 2 mm
Coverage — primer Nitoprime 25: 5.5 – 6.5 m²/litre
Pack sizes Topcoat 15 litre (base, hardener, aggregate, colour pot); Undercoat 2.4 litre (base + hardener); Nitoprime 25 in 1 & 4 litre
Minimum application temperature 15°C
Substrate Concrete or steel; concrete ≥28 days old, moisture <5%, with damp-proof membrane
Certification CPRI (Central Power Research Institute) certified for charge dissipation
Shelf life 12 months in dry, cool, unopened original packs

Industry use cases

Electronics & Semiconductors

Assembly lines, PCB and component-handling areas where a single ESD event can scrap high-value parts — the sub-0.01s static decay and 5×10⁴–1×10⁶ ohm band directly protect sensitive devices.

Defence & Explosives Magazines

Ordnance, propellant and pyrotechnics stores where static ignition is a life-safety hazard; CPRI certification supports compliance in government and PSU tenders.

Pharmaceuticals & Clean Rooms

Seamless, impervious, easily cleaned conductive floors that meet both contamination-control and static-control requirements in formulation and packing halls.

Data Centres & Computer Rooms

Server halls and control rooms where charge build-up threatens equipment uptime; the dissipative grade (1×10⁶–1×10⁹ ohms) is often specified here for gentler bleed-off.

Healthcare — Operating Theatres

Conductive flooring in theatres and critical-care areas historically required where flammable anaesthetic agents or sensitive monitoring equipment are present.

Frequently asked questions

Is Fosroc Nitoflor Conductive a genuine Fosroc product available in India?
Yes. It is part of Fosroc’s Nitoflor industrial-flooring range, supplied in India as the Nitoflor SL Conductive / Dissipative system and manufactured by Fosroc Chemicals (India) Pvt. Ltd. The system is CPRI-certified for charge dissipation. Space Arc Engineering supplies and applies it as an authorised Fosroc distributor and applicator across Delhi NCR and Pan-India.
What is the difference between the conductive and dissipative grades?
They differ in target resistance to earth. The conductive grade holds 5×10⁴–1×10⁶ ohms for faster charge bleed-off, suited to electronics and explosives areas. The dissipative grade sits higher at 1×10⁶–1×10⁹ ohms, giving slower, controlled discharge preferred in data centres and some clean rooms. The build-up and application method are otherwise similar.
How is the static charge actually carried to earth?
Through two linked elements: a low-resistance conductive undercoat (3×10³–9×10³ ohms) applied across the whole floor, and a network of copper earthing strips placed at the perimeter and across every movement joint, all tied to the building earth. The 2 mm topcoat sits on top. If the earthing grid or undercoat coverage is wrong, the floor will not perform — which is why on-site resistance testing is mandatory.
What thickness and coverage should I budget for?
The topcoat is laid at 2 mm, giving about 7.5 m² per 15-litre pack. The conductive undercoat covers 6.3–7.3 m²/litre and Nitoprime 25 primer 5.5–6.5 m²/litre. These rates are not flexible — the undercoat coverage in particular directly sets the floor’s electrical performance, so it must be held precisely.
What substrate condition is required before application?
A sound concrete (or steel) substrate, protected by a damp-proof membrane. New concrete should be at least 28 days old with moisture content below 5%, free of laitance, oil, grease and curing-compound residue. Major defects must be repaired (e.g. with Nitomortar S) because at 2 mm the topping will not hide an uneven slab. It must not be applied below 15°C.
How does it compare with Sika, Dr. Fixit and other ESD flooring brands?
Sika (Sikafloor ESD/conductive ranges), MYK/MBS, STP and BASF/MBCC offer comparable conductive epoxy systems, and Dr. Fixit (Pidilite) competes more in general flooring than dedicated ESD. The deciding factors are usually the certified resistance band, the quality of the earthing design, and applicator track record — not headline price. For projects already specifying Fosroc products, Nitoflor Conductive keeps the system, warranty and technical support under one accountable supplier.

How we position Fosroc Nitoflor Conductive

Fosroc Nitoflor Conductive sits at the specialist, performance-critical end of Fosroc’s industrial-flooring portfolio. Within the Fosroc range it pairs naturally with Nitoprime 25 (its mandatory primer), Nitomortar S for substrate repair, and the broader Nitoflor family — Nitoflor SL self-levelling toppings for general areas, Nitoflor FC/heavy-duty screeds for high-abrasion zones, and Nitoflor EPU Conductive & Dissipative where a tougher PU-hybrid ESD floor with better thermal-cycling resistance is needed. A typical building might use Nitoflor Conductive only in the ESD-critical bays and a standard epoxy elsewhere. Against the wider market, credible alternatives include Sika’s Sikafloor conductive/ESD systems, MYK/MBS and STP conductive epoxies, and BASF/MBCC ranges; Dr. Fixit (Pidilite) is a strong general-flooring competitor but less focused on certified ESD work. Where a project specification calls for CPRI-certified charge dissipation, a documented resistance-to-earth band, and a single applicator accountable for the earthing design — as in defence magazines, electronics plants and pharma clean rooms — Nitoflor Conductive is a well-proven, specification-grade choice. Space Arc Engineering’s value is not just supply but the surface prep, copper-earthing layout and on-site electrical verification that turn the datasheet number into a floor that actually performs.

Source Fosroc Nitoflor Conductive for your project

Authorised distribution, technical advice & professional application across Delhi NCR and Pan-India.


Scroll to Top