MC-Crete 500 — Calcium Nitrite-Based Anodic Corrosion Inhibitor Admixture for Reinforced Concrete in Chloride Environments — Marine Structures, Bridge Decks, Coastal Buildings, and Chloride-Exposed Infrastructure

MC-BAUCHEMIEAuthorised distributor

MC-Bauchemie MC-Crete 500

A calcium nitrite based, chloride-free corrosion inhibitor dosed into fresh concrete to protect reinforcement in marine, coastal and de-icing salt environments.

BrandMC-BauchemieCategoryConcrete AdmixturesFormA liquid calcium nitrite anodic corrosion inhibitor from MC-Bauchemie, batched into concrete to raise the chloride…

What is it?

A liquid calcium nitrite anodic corrosion inhibitor from MC-Bauchemie, batched into concrete to raise the chloride level rebar can tolerate before it starts to rust.

Where is it used?

Marine and coastal RCC, bridge decks and parapets, multi-storey car park decks, and piles cast into chloride-contaminated ground.

Why use it?

It buys durability. By lifting the critical chloride threshold, it delays the onset of reinforcement corrosion and extends the service life of structures that would otherwise spall early.

How is it applied?

Added to the mixing water or fresh concrete at the batching plant at roughly 10 to 30 litres per cubic metre, depending on the chloride exposure the mix is designed for.

About MC-Bauchemie MC-Crete 500

MC-Crete 500 is MC-Bauchemie’s calcium nitrite corrosion inhibitor, supplied as an aqueous solution that goes into the concrete at the mixing stage rather than onto the finished surface. It is a preventive admixture, chosen at the design stage for structures where chlorides are a known threat over the decades of service life ahead. The active chemistry, calcium nitrite, is entirely chloride-free, so nothing in the product itself works against the reinforcement it is meant to protect.

The way engineers should think about it is as insurance built into the mix. Ordinary reinforced concrete tolerates only a small amount of chloride at the steel before the passive oxide film breaks down and corrosion begins. MC-Crete 500 pushes that tolerance level considerably higher, so it takes far more chloride ingress, and far more time, before the reinforcement is at risk. For a jetty, a coastal slab or a car park deck salted every winter, that margin is the difference between a structure that lasts its full design life and one that starts spalling within a decade.

The technical insight

The mechanism is electrochemical, not a barrier. Steel in sound concrete is protected by a thin passive oxide layer held in place by the high alkalinity of the pore solution. Chloride ions that diffuse in eventually depassivate that film at discrete anodic sites, and once an anode forms, pitting corrosion runs. Nitrite ions from MC-Crete 500 compete for those same anodic sites: they oxidise the exposed iron and repair the passive film faster than chloride can break it down, effectively re-stabilising the steel. Because it acts at the anode, it is classed as an anodic inhibitor. The practical result is a shift in the critical chloride threshold, from roughly 0.2 to 0.4 percent chloride by weight of cement in an uninhibited mix up to about 0.6 to 1.2 percent when dosed. The nitrite does not stop chloride entering the concrete; it changes how much chloride the steel can sit in before corrosion initiates, which is why correct dosage relative to the expected chloride load matters so much.

Where it is used

  • Reinforced concrete for marine and coastal structures in EN 1504 exposure classes XS1, XS2 and XS3
  • Bridge decks and parapets subject to de-icing salt run-off
  • Multi-storey car park decks and ramps exposed to salt carried in on vehicles
  • Reinforced concrete piles cast into chloride-contaminated or aggressive ground
  • Jetties, sea walls and other splash-zone RCC where chloride ingress is continuous
  • Precast and ready-mix concrete specified for extended design service life in aggressive exposure
  • Water-retaining and coastal infrastructure where early rebar corrosion would be costly to repair
  • New-build RCC where corrosion protection is designed in at the mix stage rather than retrofitted

Key advantages

  • Raises the critical chloride threshold at the steel, giving a quantifiable, design-usable durability gain
  • Calcium nitrite chemistry is chloride-free, so it adds no aggressive ions of its own
  • Backed by decades of international field performance data on nitrite inhibitors
  • Dual action: alongside corrosion protection it gives a mild early-strength gain, useful for faster form turnaround
  • Compatible with supplementary cementitious materials such as fly ash and GGBS, and with superplasticisers
  • Dosed at the batching plant, so protection is uniform through the full concrete section, not just at a surface
  • Dosage can be tuned to the expected chloride exposure rather than a one-size-fits-all rate
  • Suits both ready-mix and precast production without special equipment

Limitations & considerations

  • It inhibits corrosion at the steel but does not reduce chloride ingress; concrete cover, low w/c ratio and good compaction still do the primary work
  • As an accelerator it mildly speeds initial and final set, which can be a problem in hot weather placements
  • Retarder dosage often needs adjusting to keep workability retention when both admixtures are used together
  • Dosage must be matched to the anticipated chloride load; under-dosing leaves the threshold too low for the exposure
  • It is a design-stage, in-mix solution and cannot be applied to hardened or existing concrete
  • Trial mixes are needed to confirm setting, strength and workability with the specific cement and SCMs in use

Selection & best practice

Treat MC-Crete 500 as part of the durability design, not an afterthought. Fix the dosage from the expected chloride exposure and the target threshold, typically somewhere in the 10 to 30 litres per cubic metre band, and always run trial mixes with the actual cement, SCMs and other admixtures before production. Add it into the mixing water or fresh concrete at the batching plant so it disperses evenly through the batch. Because it accelerates set, plan for it in hot-weather concreting: adjust retarder dosage to protect workability retention and placement time, and keep transit times realistic. Do not treat it as a substitute for good cover, a low water-cement ratio, proper compaction or curing, all of which control how fast chloride reaches the steel in the first place. Document the dosage on the mix design so it is traceable at the site.

Specifications

Product type Anodic corrosion inhibitor admixture
Active chemistry Calcium nitrite (Ca(NO2)2) aqueous solution
Chloride content Chloride-free
Typical dosage 10 to 30 litres per cubic metre of concrete
Critical chloride threshold shift From 0.2-0.4% to 0.6-1.2% Cl by weight of cement
Effect on early strength Mild acceleration, approx. 10-20% higher 1-3 day strength
Effect on set time Mild acceleration of initial and final set
IS 9103 classification Type C (accelerating admixture)
Relevant standards IS 456, IS 1343, EN 1504 exposure classes

Industry use cases

Marine and Ports

Jetties, sea walls and splash-zone RCC where continuous chloride exposure would otherwise depassivate rebar early; the raised threshold extends the interval before corrosion initiates.

Bridges and Highways

Decks and parapets hit by de-icing salt run-off, where corrosion protection is designed into the deck concrete to cut long-term repair cycles.

Car Parks

Multi-storey deck slabs and ramps exposed to salt tracked in on vehicles through winter, a classic early-spalling scenario the inhibitor is well suited to.

Foundations and Piling

Reinforced piles cast into chloride-contaminated or aggressive ground, where the steel is out of reach for future inspection or repair.

Coastal Infrastructure

New-build RCC along the coast specified for an extended design service life, where in-mix protection is more economical than later remediation.

Frequently asked questions

Does MC-Crete 500 stop chloride from getting into the concrete?
No. It does not act as a barrier and does not slow chloride ingress. It works at the steel, raising how much chloride the reinforcement can tolerate before corrosion begins. Cover depth, a low water-cement ratio and good compaction are still what control the rate of ingress.
Will it affect setting time and strength?
Yes, mildly. It classes as an accelerator (IS 9103 Type C), so it speeds initial and final set and gives roughly 10-20% higher 1 to 3 day strength. In hot weather you will usually need to adjust retarder dosage to keep workability retention.
How much do I dose per cubic metre?
Typically 10 to 30 litres per cubic metre, set by the chloride exposure you are designing for and the threshold you need. Higher chloride environments call for higher dosage. Confirm the figure with trial mixes using your actual cement and admixtures.
Is it compatible with fly ash, GGBS and superplasticisers?
Yes. It is compatible with common supplementary cementitious materials and with superplasticisers. As with any multi-admixture mix, run trial batches to confirm set, strength and workability with your specific combination.
Can it be applied to an existing structure that is already corroding?
No. MC-Crete 500 is an in-mix admixture added at batching, so it is a design-stage choice for new concrete. Existing or hardened concrete needs different, surface-applied or migrating corrosion-inhibitor systems.
Does the calcium nitrite itself add any chloride risk?
No. The product is chloride-free, so the inhibitor introduces no aggressive chloride ions of its own into the concrete. All of the chloride the steel sees comes from the external environment, not from the admixture.

How we position MC-Bauchemie MC-Crete 500

MC-Crete 500 sits in MC-Bauchemie’s admixture range as the corrosion-protection specialist, and pairs naturally with the rest of a durability-focused mix design: MC-Bauchemie’s Centrament and MC-PowerFlow superplasticiser families for water reduction and workability, alongside their waterproofing admixtures where reducing chloride ingress in the first place is part of the strategy. For chloride-exposed structures we often specify it together with a low-permeability concrete and protective coatings rather than in isolation. Where a project standardises on Fosroc, we supply the directly equivalent calcium nitrite inhibitor, and for surface protection over completed marine RCC we can bring in protective anti-carbonation and anti-chloride coatings from our Fosroc and Dr. Fixit ranges. Talk to Space Arc for the full corrosion-protection scheme rather than a single product.

Preferred brand · Fosroc equivalent

Fosroc Conplast CN — A specifier standardised on the Fosroc admixture range, or matching an existing Fosroc-approved mix design, would choose Conplast CN as the directly equivalent calcium nitrite corrosion inhibitor.

Compare with Fosroc Conplast CN →

Source MC-Bauchemie MC-Crete 500 for your project

Authorised distribution, technical advice & professional application across Delhi NCR and Pan-India.