Cold-applied rubberised bitumen waterproofing for foundations, retaining walls and buried concrete — a flexible black film laid down by brush or roller, with no heating plant on site.
What is it?
A solvent-based, rubber-modified bitumen waterproofing compound from Dr. Fixit (Pidilite Industries). It is supplied as a black viscous liquid, ready to use, and cures to a flexible waterproof film.
Where is it used?
Positive-side protection of below-grade concrete: foundation walls, basement retaining walls, pile caps, plinth beams, buried service ducts and culverts, before backfilling.
Why use it?
Rubber modification gives the cured film more than 50 percent elongation, so it tolerates the hairline movement that cracks plain bitumen paints. It bonds to concrete without a primer and needs no hot-bitumen boiler.
How is it applied?
Brush or roller, cold, in two to three coats at roughly 0.5-0.7 kg/m2 per coat. Recoat after 2-4 hours at 30 degrees C, then place a protection layer before backfill.
About Dr. Fixit NB Coat
Dr. Fixit NB Coat is a solvent-based rubberised bitumen compound built for one job: keeping ground moisture out of buried concrete. Applied cold by brush or roller, it dries to a continuous black film that seals foundation walls, basement retaining structures, pile caps and plinth beams before the excavation is closed. Because it is a single-component liquid, there is no hot-bitumen boiler, no blending and no torching crew — a site helper with a brush can lay down a dependable damp-proof barrier the same day the shuttering comes off and the surface is made good.
Space Arc Engineering supplies Dr. Fixit NB Coat across Delhi NCR and pan-India, and our applicator teams handle complete below-grade packages — surface preparation, coving at junctions, coating and protection prior to backfill. For estimation, work on 1.0-1.5 kg/m2 in a two-coat system; talk to us for project pricing, quantity take-offs and site support.
The technical insight
Plain bitumen paints go brittle once the carrier evaporates — the first shrinkage crack or settlement movement in the substrate telegraphs straight through the film, and the barrier fails exactly where water is waiting. NB Coat addresses this at the chemistry level. Rubber dissolved into the bitumen phase acts as an elastomeric backbone: as the solvent flashes off, it leaves a rubber-bitumen matrix with an elongation at break above 50 percent. The film stretches over hairline movement rather than fracturing, while the bitumen itself does what bitumen does best — repel liquid water and resist vapour transmission. Solvent carriage also means the compound wets into surface pores and bonds directly to sound concrete, which is why no separate primer is called for.
Where it is used
- External (positive-side) faces of foundation walls before backfilling
- Basement and below-grade retaining walls in buildings and podium structures
- Pile caps, footings and grade beams exposed to ground moisture
- Plinth beams and plinth-level damp-proofing bands
- Buried RCC service ducts, utility trenches and inspection chambers
- Box culverts and minor cross-drainage structures
- Sacrificial moisture barrier on buried concrete ahead of protection screeds or boards
Key advantages
- Cold application — no boilers, torches or hot-work permits needed on site
- Rubber-modified film with over 50 percent elongation rides over hairline substrate movement
- Bonds directly to sound, dry concrete and masonry without a primer
- Single-component, ready-to-use liquid; no mixing errors possible
- Fast recoat cycle — typically 2-4 hours at 30 degrees C in shade
- Black film makes coverage gaps and thin spots easy to spot during inspection
- Economical per square metre against membrane systems for low-risk, above-water-table work
Limitations & considerations
- Must be covered with a protection board, sheet or lean-concrete layer before backfilling — the film is easily gouged by aggregate and compaction tools
- Solvent-based: flammable during application, so no open flames nearby, and forced ventilation is needed in pits, sumps and confined excavations
- Not UV-stable — unsuitable for exposed roofs, terraces or any permanently sunlit surface
- A thin-film coating, not a membrane: where there is a high water table or sustained hydrostatic head, specify a torch-applied or sheet membrane instead
- Positive-side only; it cannot hold back water pushing from behind the coated face
- Needs a dry, clean substrate — application over damp or green concrete compromises adhesion
Selection & best practice
Start with the substrate: concrete should be cured, dry and sound, with laitance, oil, curing compound and loose particles removed. Fill honeycombs and blowholes with a repair mortar and form a cove fillet at wall-raft and wall-column junctions — sharp internal corners are where thin films fail first. Stir the material and apply the first coat by brush or roller at about 0.5-0.7 kg/m2, working it into pores. Allow 2-4 hours at 30 degrees C in shade, then apply the second coat at right angles to the first; add a third coat (total 1.3-1.7 kg/m2) where the consultant specifies. Inspect the black film against the grey concrete for holidays before sign-off. Never backfill against the bare coating — install a protection board, sheet or lean-concrete screed first, and keep ignition sources away until the solvent has fully flashed off.
Specifications
| Product type | Solvent-based rubberised bitumen waterproofing compound |
| Form | Black viscous liquid, single component, ready to use |
| Application method | Cold applied by brush or roller |
| Coverage (two-coat system) | Approx. 1.0-1.5 kg/m2 |
| Consumption per coat | Approx. 0.5-0.7 kg/m2 |
| Recommended coats | 2 to 3 |
| Total consumption (three coats) | Approx. 1.3-1.7 kg/m2 |
| Drying time between coats | 2-4 hours at 30 deg C in shade (varies with temperature and humidity) |
| Elongation at break (cured film) | Greater than 50 percent |
Industry use cases
Residential & Group Housing
Damp-proofing basement retaining walls and plinth beams in villas and tower blocks, keeping ground moisture out of habitable lower floors and finishes.
Commercial Basements
Positive-side coating on multi-level basement car-park walls and lift-pit externals ahead of backfill, on sites above the water table.
Infrastructure & Utilities
Box culverts, buried cable and pipe ducts, inspection chambers and utility trenches where a fast, economical buried-concrete barrier is needed.
Industrial Plants
Pile caps, equipment foundation blocks, underground pits and grade beams in factory and warehouse construction across NCR industrial belts.
Institutional Projects
Foundations and below-grade walls of schools, hospitals and office campuses where consultants specify a rubberised bitumen damp-proof coat before backfilling.
Frequently asked questions
How much NB Coat should I budget for a basement wall?
Does it need a primer on concrete?
Can I use it on the inside face of a leaking basement?
How soon can we backfill after coating?
Is it suitable for terraces or exposed roofs?
What surface preparation is required?
How we position Dr. Fixit NB Coat
Dr. Fixit NB Coat is the economical workhorse for positive-side damp-proofing where the water table sits below the structure. When the ground conditions get tougher, step up within the same family: Dr. Fixit Torchshield APP membranes for sustained hydrostatic head, Dr. Fixit Bitufix where a water-based bitumen emulsion suits odour-sensitive or enclosed sites, and Dr. Fixit Pidiproof LW+ dosed into the concrete itself for belt-and-braces protection. Pair basements with Dr. Fixit Newcoat on the exposed roof and Bathseal systems in wet areas for a single-brand envelope. Space Arc also stocks comparable below-grade systems from Fosroc (Nitoproof range) and MC-Bauchemie (Nafuflex range) — ask us which fits your bill of quantities best.
Related Waterproofing products
Source Dr. Fixit NB Coat for your project
Authorised distribution, technical advice & professional application across Delhi NCR and Pan-India.