A thixotropic, two-component structural epoxy that bonds steel plates and CFRP laminates to concrete for externally bonded reinforcement, engineered to EN 1504-4 for load transfer without drilling or mechanical fastening.
What is it?
A two-part, non-sag epoxy paste adhesive from MC-Bauchemie’s structural strengthening range, formulated to bond steel plates and carbon-fibre (CFRP) laminates onto concrete as externally bonded reinforcement (EBR).
Where is it used?
Flexural and shear strengthening of beams, slabs and bridge girders; column confinement; and any retrofit where added tensile capacity is needed on existing reinforced-concrete members.
Why use it?
It creates a stiff, high-strength adhesive bond line that transfers load between the substrate and the plate or laminate, so strengthening can be added without drilling, welding or reducing the clear headroom of the member.
How is it applied?
Both faces are prepared, the paste is buttered onto the substrate and the plate/laminate at 1 to 3 mm thickness, then pressed home and held under light pressure until cured.
About MC-Bauchemie MC-Compliform 50
MC-Compliform 50 is the structural bonding adhesive that sits at the heart of an externally bonded reinforcement job. When an existing beam, slab or column no longer carries the loads a change of use or a revised code now demands, engineers add tensile capacity on the outside of the member rather than rebuilding it. The steel plate or CFRP laminate does the structural work, but it is only as good as the glue line that couples it to the concrete. This is where the adhesive earns its place: a two-component, thixotropic epoxy that cures to a rigid, high-modulus solid and transfers shear across the interface without slip. Because it is buttered on as a paste rather than injected, it holds its shape on vertical and overhead faces and fills the minor undulations left by grinding or blasting.
For Space Arc’s engineering and contracting clients across Delhi NCR and pan-India, the appeal is practical. Strengthening with a bonded system means no percussion drilling that could hit congested rebar, no hot works near occupied space, and negligible loss of section or clear height. The product is formulated within the MC-Bauchemie MC-DUR CFK structural-strengthening philosophy and is intended to meet the structural-bonding requirements of EN 1504-4, so it slots into a specification that consultants and third-party checkers already recognise. As authorised distributor and applicator, Space Arc supplies the adhesive alongside the plates, laminates and surface-prep support needed to close out the full EBR scope on site.
The technical insight
Externally bonded reinforcement works only if the adhesive can drag load out of the reinforcing element and into the concrete faster than the interface can peel or shear apart. MC-Compliform 50 does this through a bisphenol-A epoxy resin cross-linked by an amine hardener into a dense, rigid network. Once cured, that network has a high elastic modulus, so under load it barely deforms and the plate or laminate is forced to strain in step with the concrete, mobilising its tensile capacity almost immediately. The thixotropic (non-sag) rheology is deliberate: a runny adhesive would slump off a soffit or a column face and starve the bond line, whereas this paste stays put at the full 1 to 3 mm build on each face. The controlling failure mode in a correctly executed joint is cohesive failure in the concrete itself, not at the glue line, which is exactly what a well-detailed EBR system is designed to achieve. That is also why substrate preparation is non-negotiable, laitance and weak surface material have to be removed so the bond forms into sound aggregate rather than a fragile skin.
Where it is used
- Flexural strengthening of RC beams and slabs by surface-bonding steel plates to the tension face
- Bonding CFRP laminates to bridge girders and floor beams to raise moment capacity
- Shear strengthening of beams using externally bonded plates or laminate strips
- Column and pier confinement in conjunction with wrapping or plate systems
- Retrofit of structures for change of use, higher live loads or revised code demands
- Reinstating capacity in members weakened by corrosion, overload or design deficiency
- Strengthening around new openings cut into existing slabs and walls
- Bond-critical repairs where a rigid, high-strength structural glue line is specified
Key advantages
- Non-sag paste consistency holds full bond-line thickness on vertical and overhead faces
- High-modulus cured epoxy transfers shear efficiently for genuine composite action
- Adds tensile capacity without drilling, welding or loss of clear headroom
- Bonds both steel plate and CFRP laminate, so one adhesive covers multiple EBR methods
- Formulated to the structural-bonding requirements of EN 1504-4 for specification confidence
- Ambient cure on site with no heat or specialist curing equipment needed
- Workable pot life gives crews time to position and adjust plates before set
- Supported on site by Space Arc as authorised distributor and applicator
Limitations & considerations
- It is a structural adhesive, not a repair mortar, defects, spalls and profile must be made good first
- Performance depends entirely on substrate preparation and clean, sound concrete and steel
- Epoxy cure slows markedly in cold conditions and the working window shortens in Indian summer heat
- Not a standalone crack-injection or gap-filling product for wide voids
- Requires competent structural design and detailing of the EBR system by a qualified engineer
- Blasted steel must be bonded promptly before flash rusting compromises the interface
Selection & best practice
Get the substrate right before the adhesive ever comes out. Concrete should be shot-blasted or angle-ground to expose clean, sound aggregate (a CSP 4 to 5 profile), with all laitance, curing compounds and weak material removed and the surface dry and dust-free. Steel plates should be grit-blasted close to Sa 2.5 and bonded within a few hours to beat flash rusting. Mix Components A and B in full, factory-supplied ratios only, never split a kit, and mix mechanically until uniform in colour. Apply the paste to both the substrate and the plate or laminate at 1 to 3 mm, press the element home to squeeze out a small continuous bead of adhesive along the edges, and hold it with props or temporary fixings until set. Keep an eye on pot life in hot weather, mix smaller batches when the deck is warm, and where the design calls for it, keep the member shored until the adhesive has developed strength.
Specifications
| Product type | Two-component structural epoxy bonding adhesive (EBR) |
| Chemical basis | Bisphenol-A epoxy resin (Comp. A) with amine hardener (Comp. B) |
| Consistency | Thixotropic, non-sag paste |
| Application thickness | 1 to 3 mm per bonded face |
| Bonds to | Steel plate and CFRP laminate on concrete substrate |
| Standard | Formulated to EN 1504-4 (structural bonding) |
| Substrate prep (concrete) | Shot-blast / grind to clean sound aggregate, ~CSP 4-5 |
| Substrate prep (steel) | Grit-blast to ~Sa 2.5, bond before flash rusting |
| Cure | Ambient cure on site; keep member shored where design requires |
Industry use cases
Bridges & Infrastructure
Bonding CFRP laminates to the soffits of girders and deck slabs to raise moment capacity for heavier traffic loading without closing the structure for reconstruction.
Commercial & Institutional Buildings
Plate- and laminate-bonding of beams and slabs when a floor is repurposed for higher live loads, plant rooms or new openings cut through existing framing.
Industrial Structures
Strengthening RC members carrying upgraded equipment, crane loads or storage that exceed the original design intent, with minimal disruption to operations.
Seismic Retrofit & Rehabilitation
Adding external tensile reinforcement to columns, beams and joints as part of a wider retrofit to bring older reinforced-concrete stock up to current demands.
Repair of Deteriorated Concrete
Reinstating lost structural capacity after corrosion or overload, once the concrete has been repaired and profiled back to a sound bonding surface.
Frequently asked questions
Can MC-Compliform 50 bond both steel plates and CFRP laminates?
Does it need drilling or mechanical anchors?
What surface preparation does it need?
Which standard does it work to?
How thick should the adhesive layer be?
Is design and installation something we can do ourselves?
How we position MC-Bauchemie MC-Compliform 50
MC-Compliform 50 is the adhesive layer of a complete externally bonded reinforcement system, and it should be specified alongside the elements it bonds. From the same MC-Bauchemie MC-DUR CFK family, pair it with MC-DUR CFRP laminates and CF-sheets for the tensile reinforcement itself, and use MC-DUR levelling and priming products to make the concrete profile good before bonding. Where a client’s specification is built around Fosroc, the equivalent scope is covered by the Fosroc Nitowrap system rather than a like-for-like adhesive swap. Space Arc supplies both families, so the choice can follow the consultant’s approved-vendor list rather than forcing one brand onto a job.
Fosroc Nitowrap EP(CF) — Choose the Fosroc Nitowrap CFRP system when the strengthening scheme is a wet-laid carbon-fibre fabric wrap and the specification is already standardised on Fosroc’s approved-vendor list.