Fosroc Galvashield DAS Jacket Type M
Mortar-filled galvanic jacket with alkali-activated zinc anodes — restores spalled piles and delivers ongoing galvanic cathodic protection in one operation, no external power.
What is it?
A modular, mortar-filled galvanic jacket system (the ‘Type M’ configuration of the Fosroc/Vector Galvashield DAS Jacket family) that encases corroding concrete or steel piles and columns. Self-activated zinc DAS anodes sit inside a stay-in-place PVC/FRP jacket; the annular space is filled with cementitious grout to both repair lost section and power the cathodic protection.
Where is it used?
Marine jetties, port piles, bridge piers and columns, sea-facing and coastal RCC structures, and non-marine columns across Delhi NCR and pan-India where reinforcement is corroding above and through the splash/tidal zone.
Why use it?
It rebuilds spalled concrete and provides ongoing galvanic current in a single, low-maintenance step — no impressed current, no rectifiers, no external power, and minimal downtime because the structure can usually stay in service.
How is it applied?
Break out delaminated concrete, grit/hydro-blast to clean steel, establish electrical continuity to the rebar, set the modular jacket and zinc anodes around the member, then fill the annulus with cementitious grout/concrete. The system becomes operational as soon as anode and rebar leads are connected.
About Fosroc Galvashield DAS Jacket Type M
Fosroc Galvashield DAS Jacket Type M is part of the Galvashield DAS (Distributed Anode System) family, a galvanic corrosion-protection technology developed by Vector Corrosion Technologies and supplied in India through Fosroc and its authorised distribution network, including Space Arc Engineering. The “Jacket” products take the Galvashield DAS anode and package it for the most demanding situation a corrosion engineer faces in Indian conditions: piles and columns where chloride-driven reinforcement corrosion has already cracked and spalled the cover concrete, particularly through the splash and tidal zone of coastal and marine structures. The “Type M” designation refers to the mortar-filled modular jacket configuration, where the annular gap between the host member and a stay-in-place PVC or FRP jacket is filled with portland cement concrete or repair mortar that simultaneously reinstates lost section and embeds the anodes. At the heart of the system are the alkali-activated zinc DAS anodes — high-purity zinc cast around steel tie wires within an enhanced cement-based mortar held at an internal pH of 14 or greater. That high-alkalinity environment keeps the zinc anodically active for the life of the system without depending on saltwater contact, which is the key reason a single jacket product can work in the wet tidal zone, the damp splash zone, the dry upper pile and even in non-marine columns. Once the rebar is made electrically continuous and connected to the anodes, the zinc preferentially corrodes in place of the steel, supplying protective galvanic current that the system self-regulates according to the corrosion rate and environment. The result is a self-powered, near-zero-maintenance protection layer that does not need rectifiers, wiring runs to a power supply, or the ongoing monitoring burden of an impressed-current cathodic protection (ICCP) installation. For Indian asset owners — port trusts, bridge authorities, coastal industrial plants and infrastructure operators — this combines two jobs that are usually separate (structural patch repair and corrosion mitigation) into one specialist operation, which is why the DAS Jacket sits firmly in the protective coatings and corrosion-control segment rather than being a plain repair mortar.
The technical insight
The defining engineering feature is the alkali-activated anode mortar (internal pH 14 or greater) cast around the zinc. In ordinary galvanic anodes, the zinc passivates as its surrounding environment loses alkalinity and the current output collapses; the enhanced high-pH mortar in the DAS anode keeps the zinc surface depassivated and electrochemically active across wet, damp and dry exposure zones — this is what lets one jacket protect submerged, tidal, splash and dry pile sections without relying on chloride/saltwater activation. The DAS anode itself is supplied in two distributed sizes — DAS at 28 x 38 mm carrying 890 g/m of zinc (0.6 lb/ft) and the higher-output DAS-X at 32 x 50 mm carrying 2,450 g/m of zinc (1.65 lb/ft) — so the designer scales zinc mass (and therefore total current capacity and service life) to the steel density and chloride load of the specific member. Because output is governed by the corrosion cell, the system self-regulates: current rises where steel is actively corroding and tapers where it is passive, which independent test programmes have shown can meet the NACE/AMPP cathodic protection criterion of a minimum 100 mV potential shift. For deep marine piles, the jacket is typically paired with a bulk zinc anode (around 48 lb / ~22 kg) installed below mean low tide and wired up into the jacket junction box to cover the permanently submerged section that the jacket above cannot reach.
Where it is used
- Galvanic cathodic protection of chloride-contaminated, corroding RCC piles in marine and coastal structures
- Repair and protection of bridge piers and columns showing spalling and rebar corrosion
- Splash- and tidal-zone protection of jetty, wharf and port piles above the permanently submerged section
- Protection of prestressed concrete piling and steel H-piles in aggressive exposure
- Single-step concrete reinstatement plus corrosion mitigation on coastal industrial and infrastructure columns
- Non-marine RCC columns affected by carbonation- or chloride-induced corrosion where impressed-current CP is not justified
- Combined use with other Galvashield embedded anodes as part of a whole-structure corrosion management strategy
Key advantages
- Two operations in one: reinstates spalled/lost concrete section and delivers ongoing galvanic protection in a single installation
- Self-powered and self-regulating — no external power, no rectifiers, no transformer/rectifier housing, near-zero maintenance
- Alkali-activated zinc anodes (internal pH 14+) stay active in wet, damp and dry zones without relying on saltwater contact
- Works across marine, brackish, freshwater and non-marine exposures, making it versatile for varied Indian coastal and inland assets
- Long service life — 10 to 40 years depending on zinc mass, steel density, chloride level and humidity
- Meets the NACE/AMPP 100 mV potential-shift cathodic-protection criterion in independent test programmes
- Modular stay-in-place PVC/FRP jacket gives a clean, durable finished appearance and can be round or square in custom lengths
- Most work can be done with the structure in service, minimising operational downtime
- Anode performance can be monitored if required, but monitoring is optional unlike most ICCP systems
Limitations & considerations
- A galvanic (sacrificial) system — total current output is finite and lower than impressed-current CP, so it is sized for the design life and cannot be ‘turned up’ later
- Service life is project-specific and falls with higher reinforcement density, higher chloride concentration, very high conductivity concrete and high humidity
- Performance depends on the rebar being electrically continuous; discontinuous steel must be bonded before the system will work correctly
- Permanently submerged pile sections below mean low tide generally need a supplementary bulk zinc anode — the jacket alone does not cover them
- Not a structural strengthening product; where structural damage exists a structural engineer must assess load capacity separately
- Requires correct surface preparation (breaking out unsound concrete, grit/hydro-blasting steel) and trained installation for the anodes to function as designed
- Higher first cost than a plain repair mortar; the value is realised over the extended maintenance-free service life, not on day one
Selection & best practice
Treat the Type M jacket as a designed cathodic-protection system, not just a repair. Begin with a corrosion survey — half-cell potentials, chloride profiling and cover/carbonation depth — so the zinc mass (DAS vs DAS-X) and anode spacing are sized to the actual steel density and chloride load. Break out all delaminated and unsound concrete, then grit- or hydro-blast to remove corrosion product from the steel before fitting anodes. Confirm and, where needed, establish electrical continuity of the reinforcement, and verify the connection to the anode lead wires before grouting. Use the specified cementitious grout/concrete to completely fill the annular space with no voids around the anodes. For piles extending below mean low tide, design in a bulk zinc anode below the tide line wired to the junction box. Where the structure is cracked or load-affected, involve a structural engineer in parallel. Finally, fit and read reference electrodes at commissioning to baseline the 100 mV criterion, even on jobs where ongoing monitoring is not contractually required.
Specifications
| Product type | Galvanic (sacrificial) anode jacket for cathodic protection of concrete/steel piles and columns |
| Type M configuration | Mortar/concrete-filled modular jacket — annular space filled with portland cement concrete or repair mortar |
| Anode technology | Alkali-activated zinc DAS (Distributed Anode System) anodes, self-activated |
| Anode composition | High-purity zinc cast around steel tie wires within enhanced cement-based mortar, internal pH 14 or greater |
| DAS anode size / zinc | 28 x 38 mm, 890 g/m of zinc (0.6 lb/ft) |
| DAS-X anode size / zinc | 32 x 50 mm, 2,450 g/m of zinc (1.65 lb/ft) |
| Jacket material | Modular polyvinyl chloride (PVC) or fibre-reinforced polymer (FRP), stay-in-place or removable formwork |
| Jacket geometry | Round or square; supplied in custom lengths to suit the project |
| Optional bulk anode | ~48 lb (~22 kg) zinc anode installed below mean low tide for submerged sections |
| Levels of protection | Corrosion prevention, corrosion control, and cathodic protection (per design) |
| Performance criterion | Meets NACE/AMPP 100 mV minimum potential-shift cathodic-protection criterion |
| Power requirement | None — self-powered galvanic system, no external power or rectifier |
| Service life | 10 to 40 years (project-dependent on steel density, chloride, humidity, anode mass) |
| Exposure suitability | Marine, brackish, freshwater and non-marine; tidal, splash, dry pile and column sections |
| Maintenance | Low / near-zero; anode performance optionally monitorable |
Industry use cases
Ports & Marine
Rehabilitating corroding RCC and prestressed piles at jetties and wharves on India’s coastline, restoring section and protecting the splash/tidal zone while berths remain operational.
Bridges & Highways
Galvanic protection of bridge piers and columns over tidal creeks and coastal estuaries where chloride ingress has cracked the cover, avoiding the cost and power infrastructure of impressed-current CP.
Coastal Industrial Plants
Protecting structural columns and pile caps at sea-facing power, desalination, fertiliser and petrochemical facilities exposed to airborne chlorides and humid splash conditions.
Water & Wastewater
Mitigating reinforcement corrosion in columns and support members of intake structures and treatment works in brackish and aggressive environments.
Heritage & Asset Life-Extension
Extending the service life of ageing concrete jetty and pier structures with a low-disruption, near-maintenance-free system as part of a planned corrosion-management programme.
Frequently asked questions
What does ‘Type M’ mean in Galvashield DAS Jacket Type M?
Is this a structural repair or a corrosion-protection product?
Does it need external power like ICCP systems?
How long does it last in Indian coastal conditions?
Can it protect the fully submerged part of a pile?
How does it compare to other corrosion-protection options in India?
How we position Fosroc Galvashield DAS Jacket Type M
Galvashield DAS Jacket Type M occupies the specialist niche where structural patch repair and corrosion mitigation must happen together on piles and columns — typically chloride-attacked marine and coastal RCC. Within the Fosroc/Vector galvanic range it complements the embedded discrete anodes (Galvashield XP, CC, R, and the broader Galvashield DAS embedded forms) and the distributed Galvashield DAS used in patch and deck repairs; the Jacket is the format you reach for when the member is already spalling and needs section reinstated. Against impressed-current cathodic protection (ICCP) it positions as the lower-maintenance, no-power alternative for assets where running a rectified system is not justified, accepting a finite galvanic current budget in exchange. Compared with competitor galvanic and CP systems — Sika (FerroGard embedded anodes and Sika galvanic/CP ranges), MBS, and STP/cathodic-protection specialists — its differentiator is the alkali-activated anode that stays active across wet-to-dry exposure plus the integrated jacket-and-fill delivery. It should not be confused with plain polymer-modified repair mortars (Fosroc Renderoc, Sika MonoTop, Dr. Fixit repair systems), which reinstate concrete but provide no ongoing cathodic protection; the honest framing for a client is that the DAS Jacket costs more upfront and is justified by extended, near-maintenance-free service life on high-value corroding pile and column assets.
Related Protective Coatings products