Fosroc Proofex Total
A BBA-approved, five-layer aluminium-cored membrane that combines a total gas barrier against methane, radon, carbon dioxide and hydrocarbons with a high-performance damp-proof membrane in a single loose-laid sheet.
What is it?
A factory-laminated, five-layer reinforced sheet membrane built around an aluminium foil core, a polyester/polypropylene reinforcing grid and outer polyolefin layers, supplied in rolls roughly 0.4 mm thick and 2 m x 50 m.
Where is it used?
Below-ground and at-grade construction on brownfield, redeveloped or gas-affected sites: ground-bearing slabs, suspended concrete, and beam-and-block floors where a combined ground-gas barrier and damp-proof membrane is specified.
Why use it?
It blocks methane, radon, carbon dioxide and hydrocarbon vapours while also acting as a damp-proof membrane, so a single loose-laid sheet replaces a separate DPM plus gas barrier, and the foil core gives effectively zero gas and vapour transmission.
How is it applied?
Loose-laid over a prepared, blinded substrate with minimum 100 mm laps that are heat-welded or sealed with Proofex Total Tape, detailed around penetrations with top hats and flashing tape, then protected before the screed or slab is cast.
About Fosroc Proofex Total
Fosroc Proofex Total is a high-performance, totally gas-impervious reinforced sheet membrane engineered for ground-floor construction on sites where soil gases and ground moisture both pose a risk. Unlike a simple polythene DPM, it is a five-layer laminate: a continuous aluminium foil layer forms the gas barrier core, a polyester/polypropylene reinforcing grid carries the mechanical load and resists puncture during laying, and outer polyolefin layers protect the foil and provide a weldable surface. The black/silver sheet is roughly 0.4 mm thick and is supplied loose-laid rather than bonded, which makes it tolerant of substrate movement and quick to install across large floor plates.
In the Indian market, where many residential, commercial and infrastructure projects are now built on reclaimed land, former industrial sites, old landfill margins and made-up ground in expanding metros such as Delhi NCR, Mumbai, Pune, Hyderabad and Bengaluru, ground-gas protection has moved from a niche requirement to a genuine design consideration. Methane and carbon dioxide from decomposing fill, radon from certain geologies, and residual hydrocarbon vapours from old fuel-handling sites can all migrate into ground floors and accumulate in poorly ventilated voids. Proofex Total is positioned for exactly these situations: it gives the structure a verified gas barrier and a damp-proof membrane in one product, reducing the number of layers, interfaces and trades on site. Because it is BBA-approved and designed to be installed and validated under recognised UK ground-gas codes, it suits projects where consultants want a documented, third-party-certified barrier rather than an improvised solution. Space Arc Engineering, as an authorised Fosroc distributor, supplies Proofex Total together with its dedicated tapes, top hats, flashing and protection board so the full certified system can be specified and delivered for Pan-India projects.
The technical insight
The performance of Proofex Total comes from its laminated build-up rather than from sheet thickness alone. The aluminium foil core is what delivers the headline figures: methane gas permeability and water vapour permeability are both quoted at 0.00 g/m2/day (tested to BR 212 and BS 3177 respectively), meaning the foil is effectively impermeable to the gases and moisture that pass through ordinary plastics over time. The polyester/polypropylene grid embedded in the laminate gives high in-plane strength and tear resistance, so the membrane survives foot traffic, reinforcement placement and the rigours of a live site without the foil cracking. Reported mechanical values include tensile strength of about 452 N/50 mm in the machine direction and 380 N/50 mm cross-direction (with heat-aged values holding at 442 and 386 N/50 mm), tear resistance around 219-221 N, elongation to break near 20%, and a bursting strength of at least 800 kPa to DIN 53141. The product is certified under BBA Agrement 21/5880 and is designed to satisfy ground-gas design and verification frameworks such as BS 8485:2015+A1:2019, with EN 13967 referenced for plastic damp-proof sheets. The single most important practical point is that the barrier is only as good as its joints and penetration details: laps must be a minimum of 100 mm and either heat-welded with specialist equipment or sealed with Proofex Total Tape, and on gas-protection projects the welds are typically integrity-tested by an independent specialist under CIRIA C735.
Where it is used
- Combined ground-gas barrier and damp-proof membrane beneath ground-bearing concrete floor slabs
- Gas and damp protection over suspended concrete and beam-and-block ground floors
- Brownfield and redeveloped sites with methane and carbon dioxide from made-up ground or old landfill
- Radon-protection layers in geologies where radon ingress is a documented risk
- Sites with residual hydrocarbon vapour contamination (where the membrane is not in direct contact with the source)
- Forming a continuous gas-resistant cavity tray, removing the need for a separate tray product
- Basements, podiums and lowest-level floors of residential, commercial and institutional buildings on gas-affected land
- Infrastructure and industrial floor build-ups requiring documented, third-party-certified ground-gas protection
Key advantages
- Two functions in one sheet: a verified ground-gas barrier and a damp-proof membrane, reducing layers and interfaces
- Aluminium foil core gives effectively zero (0.00 g/m2/day) methane and water-vapour transmission
- Resists the full common spectrum of soil gases: methane, radon, carbon dioxide and hydrocarbon vapours
- Polyester/polypropylene reinforcing grid provides high puncture and tear resistance during installation
- Loose-laid system installs quickly over large floor plates and tolerates minor substrate movement
- BBA-approved (21/5880) and aligned with BS 8485 ground-gas design, giving documented compliance for consultants
- Can be detailed to form a continuous cavity tray, eliminating a separate product
- Backed by a complete accessory range (tape, top hats, flashing, protection board) for fully sealed detailing
Limitations & considerations
- Performance depends heavily on workmanship at laps and penetrations; a poorly welded or taped joint compromises the whole barrier
- Welding requires specialist equipment and trained operatives (UK guidance references CSCS/NVQ Level 2 competence)
- Gas-protection installations generally require independent joint integrity testing (e.g. CIRIA C735), adding programme and cost
- Not designed to resist hydrostatic water pressure on its own; a positive-side waterproofing system is needed for true tanking duties
- Hydrocarbon protection applies where the membrane is not in direct, prolonged contact with the contaminant source
- Loose-laid foil membrane needs protection (board/screed) before and during follow-on trades to avoid puncture
- A site-specific gas risk assessment and design (gas characterisation, NHBC/BS 8485 scoring) must precede selection; the membrane is one part of a wider protection strategy
- Detailing around services, columns and changes in level demands care and the correct Fosroc accessories
Selection & best practice
Start with a ground-gas risk assessment and a BS 8485-style design so the protection score, ventilation and membrane choice are matched to the site characterisation before ordering. On site, lay Proofex Total over a clean, blinded, projection-free substrate and keep a minimum 100 mm lap on all joints. Heat-weld laps with the correct equipment, or seal with Proofex Total Tape where welding is impractical, and detail every penetration with Proofex Top Hats and flashing tape rather than improvising. Treat the membrane as a sealed system: avoid unnecessary penetrations, seal those that are unavoidable, and protect the laid sheet with Proofex Protection Board before reinforcement and concreting. On gas-protection projects, arrange independent integrity testing of the welds and validation in line with CIRIA C735, and retain the records for sign-off. Always use genuine Fosroc accessories from an authorised distributor and follow the current product datasheet and BBA certificate for the specific project conditions.
Specifications
| Product type | 5-layer reinforced gas barrier + damp-proof membrane (loose-laid sheet) |
| Composition | Aluminium foil core + polyester/polypropylene reinforcing grid + outer polyolefin layers |
| Colour | Black / silver |
| Nominal thickness | approx. 0.4 mm (minimum) |
| Roll size | 2 m x 50 m (approx.) |
| Minimum lap | 100 mm |
| Methane gas permeability | 0.00 g/m2/day (to BR 212) |
| Water vapour permeability | 0.00 g/m2/day (to BS 3177) |
| Gases resisted | Methane, radon, carbon dioxide, hydrocarbon vapours |
| Tensile strength | approx. 452 N/50 mm (MD) / 380 N/50 mm (CD) |
| Tear resistance | approx. 219 N (longitudinal) / 221 N (transverse) |
| Elongation at break | approx. 20% (MD and CD) |
| Bursting strength | >= 800 kPa (to DIN 53141) |
| BBA Agrement certificate | 21/5880 |
| Referenced standards | BS 8485:2015+A1:2019; EN 13967 |
| Jointing | Heat-welded or sealed with Proofex Total Tape |
| Key accessories | Proofex Total Tape, Top Hats, Flashing Tape, Protection Board |
Industry use cases
Brownfield residential development
High-rise and gated housing on reclaimed or made-up ground in Delhi NCR and other metros, where ground-bearing slabs need a combined gas barrier and DPM beneath every ground-floor unit.
Commercial and IT parks
Office and campus floor slabs over former industrial land, where consultants demand a BBA-certified, documented gas-protection layer for occupant safety and approvals.
Institutional and healthcare
Schools, hospitals and public buildings on gas-affected sites, where a verified methane/radon/CO2 barrier under the lowest floor is part of the safety case.
Landfill-margin and remediation projects
Buildings near or over capped landfill or contaminated land, paired with venting and granular blankets, using Proofex Total as the sealed membrane layer with independently tested joints.
Infrastructure and transport buildings
Stations, depots and ancillary structures on urban infill land where ground gas and damp must both be controlled under suspended or beam-and-block floors.
Industrial and warehousing floors
Distribution and manufacturing sheds on redeveloped sites needing a robust, puncture-resistant gas-and-damp barrier capable of surviving heavy follow-on trades before slab casting.
Frequently asked questions
What is Fosroc Proofex Total used for?
Which gases does Proofex Total resist?
How are the joints in Proofex Total sealed?
Is Proofex Total a tanking or basement waterproofing system?
Is Proofex Total certified, and which standards apply?
How does Proofex Total compare with a standard polythene DPM?
Can Space Arc Engineering supply Proofex Total across India?
How we position Fosroc Proofex Total
Within Fosroc’s Proofex range, Proofex Total sits at the high end as a fully certified ground-gas barrier plus damp-proof membrane. It differs from Proofex Engage, a cast-in HDPE membrane that bonds mechanically to fresh concrete for tanking, and from torch-applied bituminous membranes such as Proofex Torchseal, which target conventional waterproofing rather than gas. Where only damp control is needed, simpler Fosroc DPMs or the gas-focused Proofex 3000MR may be more economical; Total is chosen when both ground gas and damp must be addressed under one certified sheet. Against competitor systems, it competes with dedicated gas-barrier products such as those from Visqueen/Cordek and self-adhesive gas membranes used in the UK market, while in India alternatives from Sika (e.g. Sika gas-barrier and waterproofing membranes), Dr. Fixit, STP/Bondseal and MBS waterproofing typically pair a separate gas membrane with a DPM. Honest positioning: Proofex Total is strongest where a BBA-certified, documented, single-sheet gas-and-damp barrier is required on a gas-assessed site; for straightforward damp-proofing or for hydrostatic tanking it is over-specified or insufficient on its own, and a project-specific BS 8485 design should always guide the final selection.
Related Waterproofing products
Source Fosroc Proofex Total for your project
Authorised distribution, technical advice & professional application across Delhi NCR and Pan-India.