Nitocote EP405 — Two-Component Epoxy Lining for Chemical Resistant Concrete Protection

FOSROCAuthorised distributor

Fosroc Nitocote EP405

A two-pack, 100% solids epoxy lining that turns a bare concrete or steel water tank into a smooth, non-toxic, IS 9833-certified surface fit for potable water and foodstuffs.

BrandFosrocCategoryProtective CoatingsFormA two-component, solvent-free (100% solids) epoxy resin coating from Fosroc, formulated specifically for lining…

What is it?

A two-component, solvent-free (100% solids) epoxy resin coating from Fosroc, formulated specifically for lining potable water and food-contact structures. Cured film is non-toxic to IS 9833-1981.

Where is it used?

Inside potable water tanks, reservoirs, RCC sumps, silos, water treatment works, breweries, dairies and meat/food processing plants — on both concrete and mild steel.

Why use it?

It gives a hygienic, glossy, easy-clean film that resists corrosion, abrasion and a wide range of chemicals, with zero solvent odour so it can be applied inside closed tanks.

How is it applied?

Grit-blast and prime the substrate, fill blow-holes, then brush two coats at 100 microns DFT each for a 200-micron system. Overcoat after roughly 18-24 hours; cure 7 days before filling.

About Fosroc Nitocote EP405

Nitocote EP405 is Fosroc’s answer to a very specific problem: how do you protect the inside of a water tank or food-grade vessel without contaminating what it holds. It is a two-pack epoxy supplied in pre-measured base and hardener quantities, and because it is 100% solids there is no solvent to flash off — nothing to leach into stored water, and no fumes to trap you inside a confined RCC sump during application. Once mixed and brushed on, it cures to a smooth, glossy, tough film that is genuinely non-toxic, meeting the requirements of IS 9833-1981, the Indian standard for coatings in contact with potable water. That single certification is why consultants specify it for drinking-water reservoirs where an ordinary industrial epoxy would never be allowed.

Beyond potable water, the cured lining is a workhorse chemical and abrasion barrier. It bonds directly to both mild steel and concrete, so the same product lines an RCC overhead tank and the steel effluent vessel next to it. It contains no metallic particles, so it will not itself corrode, and it stands up to a broad spread of industrial chemicals — the reason it turns up in dairies, breweries, water treatment works and meat and food processing plants as much as in domestic water tanks. It is available in blue and white, and applicators typically run one colour for the first coat and the other for the second so full, unbroken coverage is easy to verify by eye. For engineers and contractors across Delhi NCR and the rest of India, it is the default lining when a tank has to be both watertight and safe to drink from.

The technical insight

The performance comes from a fully reacted, 100%-solids epoxy network. Because there is no solvent carrier, the wet film you brush on is the dry film you keep — 100 microns wet becomes essentially 100 microns dry, so a two-coat application lands reliably at the specified 200-micron minimum DFT without the shrinkage and pinholing that plague solvent-borne coatings. That dense, cross-linked film is what blocks water ingress and chemical attack, and its lack of any metallic filler is what stops the lining itself becoming a corrosion site. Adhesion is the other half of the story: bond strength to concrete exceeds 1 N/mm² (ASTM D4541), achieved by grit-blasting the substrate to open blow-holes and create a mechanical key. The epoxy is deliberately tolerant of damp concrete — a real advantage on Indian sites where a substrate is rarely bone dry — but the chemistry cannot displace liquid water, so any standing or running water must be eliminated first or the film will not wet out and bond.

Where it is used

  • Internal lining of potable water storage tanks, overhead tanks and underground RCC reservoirs
  • Coating of RCC sumps, wet wells and water treatment plant structures
  • Lining of steel and concrete vessels in breweries, distilleries and dairies
  • Protection of tanks and floors in meat, poultry and food processing plants
  • Chemical-resistant lining of industrial process vessels and containment structures
  • Corrosion protection of grit-blasted mild steel tanks and pipework interiors
  • Hygienic coating of silos and dry-goods storage where washdown is frequent
  • Refurbishment lining of existing water-retaining structures after concrete repair

Key advantages

  • Certified non-toxic to IS 9833-1981, so it is approved for direct potable-water contact
  • 100% solids and solvent-free — no odour, safe to apply inside confined tanks and sumps
  • Bonds directly to both concrete and mild steel, covering mixed-material structures with one product
  • Cures to a smooth, glossy, easy-to-clean film that resists bacterial harbourage
  • Broad chemical and abrasion resistance without any corrodible metallic fillers
  • Tolerant of damp (not wet) concrete, suiting the reality of Indian site conditions
  • Two-colour system (blue/white) makes full coverage and missed patches obvious on inspection
  • Non-flammable, simplifying storage and handling on active sites

Limitations & considerations

  • Must not be applied over existing coatings — the substrate has to be blasted back to bare concrete or steel
  • Although damp concrete is fine, there must be absolutely no standing or running water during application or cure
  • Not colour-stable in direct sunlight; a white surface bloom can form in cold or humid curing conditions (cosmetic only)
  • Do not apply below 10°C, when temperature is 10°C and falling, or when relative humidity exceeds 90%
  • Short pot life once mixed (about 60-80 min at 20°C, 45 min at 30°C), so mix only what can be used quickly
  • Full potable-water cure needs the specified curing period before the tank is filled and commissioned

Selection & best practice

Start with surface preparation, because the whole system stands or falls on it: grit-blast concrete to remove laitance and open blow-holes, and blast steel to bright metal, coating it promptly before flash rust forms. Fill blow-holes and imperfections with Nitomortar FC (or Nitocote VF) and let them harden before you begin. Mix the full hardener can into the base and stir mechanically with a slow-speed paddle, scraping the sides and bottom. Because pot life is short and the reaction is exothermic in the can, mix only what your crew can lay in the working window. Brush the first coat, scrubbing it firmly into the surface to a wet film of at least 100 microns; let it become tack-free (roughly 18-24 hours depending on temperature) then apply the second coat in the contrasting colour to the same thickness. Keep the area free of standing water throughout, and allow the full cure — 7 days at 30°C, longer in the cold — before filling a potable-water tank. Clean tools with Nitoflor Sol before the material sets.

Specifications

Product type Two-pack, solvent-free (100% solids) epoxy resin coating
Volume of solids 100%
Specific gravity (mixed) 1.85 g/cc
Colours Blue and White
Number of coats / total DFT 2 coats, 200 microns minimum total (100 microns/coat)
Theoretical coverage 10.0 m² per litre per coat at 100 microns
Pot life 60-80 min at 20°C; 45 min at 30°C
Overcoating time 24 hours at 20°C; 18 hours at 30°C
Full cure / min. temperature 7 days at 30°C; minimum application temperature 10°C

Industry use cases

Municipal & Domestic Water

Lining new and refurbished potable water reservoirs, overhead tanks and underground sumps where an IS 9833-certified, non-toxic film is mandatory before commissioning.

Food & Beverage Processing

Hygienic, easy-clean lining for tanks and vessels in dairies, breweries and meat/food plants that face frequent washdown and must stay food-safe.

Water & Effluent Treatment

Chemical and corrosion protection for RCC and steel structures at water treatment works and process vessels handling a range of industrial liquids.

Industrial Plant & Storage

Interior coating of silos, process tanks and mild-steel vessels needing a tough, abrasion-resistant barrier with no solvent fumes during confined-space work.

Frequently asked questions

Is Nitocote EP405 safe for drinking water tanks?
Yes. The cured film is non-toxic and meets IS 9833-1981, the Indian standard for coatings in contact with potable water, which is exactly why it is specified for drinking-water reservoirs and tanks. Allow the full curing period before filling and commissioning.
How many coats do I need and what thickness?
Two coats, applied at 100 microns dry film thickness each, for a 200-micron minimum total system. Running the first coat in one colour and the second in the other makes it easy to confirm full, unbroken coverage.
What is the coverage per litre?
Theoretically 10.0 m² per litre per coat at 100 microns. This is a theoretical figure — grit-blasted and porous substrates absorb more, so allow for wastage and reduced practical coverage when estimating.
Can I apply it to a damp tank?
Damp concrete is acceptable, which suits typical Indian site conditions, but there must be no standing or running water. Eliminate any active seepage and free water first, or the epoxy will not wet out and bond.
Does it work on steel tanks as well as concrete?
Yes. It bonds directly to both mild steel and concrete. Steel must be grit-blasted to bright metal and coated promptly before rust reforms; concrete must be blasted, blow-holes filled, and laitance removed.
How long before I can fill the tank?
Nitocote EP405 is fully cured in about 7 days at 30°C, with longer needed in cold weather. For potable-water service, respect the full cure before introducing water so the film reaches its non-toxic, chemically stable state.

How we position Fosroc Nitocote EP405

Nitocote EP405 is the potable-water and food-grade lining in Fosroc’s Nitocote coating family. Where the substrate simply cannot be kept free of moisture, its close sibling Fosroc Nitocote EP403 is the damp/wet-tolerant epoxy coating to specify instead. Surface preparation usually pairs it with Fosroc Nitomortar FC to fill blow-holes and imperfections before lining. For our clients weighing brands, comparable potable-water and protective-lining systems are available from Dr. Fixit, Sika and MC-Bauchemie in our range — talk to our team for a like-for-like specification. Space Arc Engineering is an authorised Fosroc distributor and applicator serving Delhi NCR and pan-India.

Source Fosroc Nitocote EP405 for your project

Authorised distribution, technical advice & professional application across Delhi NCR and Pan-India.


Scroll to Top