Fosroc Conbextra GP5
A dual shrinkage-compensated, ultra-high-strength free-flow cementitious grout built for machine bases and bridge bearings carrying both static and dynamic loads.
What is it?
A pre-bagged, single-component ultra-high-strength cementitious grout from Fosroc that mixes with clean water into a free-flowing, non-shrink pour. It sits at the top of the Conbextra GP family and complies with ASTM C1107 Type C.
Where is it used?
Under critical rotating and reciprocating machinery: turbine and compressor base plates, heavy motor and pump skids, bridge bearing pedestals, and precast connections where loads are both static and dynamic.
Why use it?
Its dual shrinkage-compensation system holds full contact under the base plate over time, so bearing area is not lost to plastic settlement or long-term drying shrinkage. That protects alignment and load transfer on high-value equipment.
How is it applied?
Presoak the foundation, box in leak-proof formwork, mix one 25 kg bag with the measured water, and pour continuously from one side into gaps up to 150 mm, then cure the exposed edges.
About Fosroc Conbextra GP5
Conbextra GP5 is Fosroc’s ultra-high-strength grade of cementitious precision grout, engineered for foundations where the equipment above is expensive, sensitive to movement, and cycles between load states. It arrives as a factory-blended dry powder in 25 kg bags, so the site crew only adds a controlled quantity of clean water. That single decision removes the batching guesswork that plagues site-mixed sand-cement grouts and gives a repeatable, non-bleed, free-flowing pour every time. The result flows into congested pockets and long travel paths on its own, wrapping tightly around anchor bolts and filling the full footprint of a base plate without vibration.
What separates GP5 from general-purpose grades is the combination of dual shrinkage compensation and a genuinely high strength ceiling. Ordinary grouts that only compensate for plastic-stage settlement can still shrink over weeks as they dry, quietly opening a gap between grout and steel. GP5 is formulated to counter movement in both the plastic and hardened phases, which is why Fosroc rates it to ASTM C1107 Type C, the grade band reserved for grouts that hold expansion at the higher end. For a turbine skid or a bridge bearing that must not lose contact, that behaviour is the whole point. Space Arc supplies GP5 as an authorised Fosroc distributor and applicator, with technical support for pour design across Delhi NCR and pan-India projects.
The technical insight
The engineering problem a machine-base grout solves is contact, not just strength. A base plate transfers concentrated load into the foundation only where grout actually touches steel; any void becomes a stress concentration, and under vibrating equipment those voids grow into fretting and eventual misalignment. Conbextra GP5 addresses this with a two-stage expansion strategy. While the grout is still plastic, a controlled gaseous expansion drives it up against the underside of the plate and compensates for the settlement and bleed that would otherwise leave a gap at the top of the pour. Then, as the matrix hydrates and matures, the mix is designed to resist the drying shrinkage that normally follows, so the contact achieved on day one is not surrendered over the following weeks. Because the blend carries no metallic iron, there is no oxidising filler to stain the concrete or corrode, and the chloride-free chemistry keeps the surrounding reinforcement and anchor bolts safe. The low water demand of the factory blend is what unlocks the high early and ultimate strength: less mixing water means a denser, stronger hardened grout that can carry both the dead weight and the fatigue loading of running machinery.
Where it is used
- Grouting base plates of steam and gas turbines, large motors and centrifugal compressors
- Bedding reciprocating machinery such as heavy-duty compressors and diesel generator sets subject to dynamic loading
- Bridge bearing pedestals and structural bearing plates
- Anchoring holding-down bolts and large-diameter anchors in critical foundation pockets
- Precast connections and column base grouting where high load transfer is required
- Filling gaps up to 150 mm in a single pour beneath heavy load-bearing units
- Grouting of pump and blower skids in process and power plants
- Rail-mounted and crane rail base grouting where alignment must be preserved under service loads
Key advantages
- Dual shrinkage compensation controls both plastic-stage settlement and long-term drying shrinkage, preserving contact under the plate
- Ultra-high-strength grade complying with ASTM C1107 Type C for the most demanding machine-base and bearing duties
- Free-flow, self-levelling consistency reaches congested pockets and long travel paths without vibration or rodding
- Factory pre-blend removes site batching variation and gives a repeatable, non-bleed, non-segregating pour
- No metallic iron content, so there is no staining and no rust-driven expansion in the hardened grout
- Chloride-free chemistry protects embedded anchor bolts and reinforcement from corrosion
- Handles both static and dynamic loads, making it suitable for vibrating rotating and reciprocating equipment
- Single-pour capability up to 150 mm reduces pour sequences and cold joints on deep sections
Limitations & considerations
- It is a cementitious grout, so for aggressive chemical exposure, oil-soaked bases or the highest fatigue duties an epoxy grout such as Conbextra EP 300 is the better specification
- Water dosage must be measured, not judged by eye; over-watering destroys the strength and expansion behaviour the product is designed for
- In hot conditions (above 40 degrees C) cool mixing water is needed, and below 10 degrees C warm water and extended formwork retention are required to develop strength
- Sections thicker than the single-pour limit need well-graded aggregate extension or staged pours to control heat build-up
- It is alkaline and generates dust when mixed, so gloves, goggles and a dust mask are mandatory
- Pours must be continuous with adequate mixing capacity on hand; a stalled pour front can trap air or presoak water beneath the plate
Selection & best practice
Success with GP5 is decided before the first bag is opened. Cut back any weak or laitance-affected concrete to a sound base, blow bolt pockets clean, and saturate the foundation for several hours beforehand, then remove all free water immediately before pouring. Build genuinely leak-proof formwork with a generous head box on the pouring side and minimal gap on the far side. Measure the clean water accurately into the mixer first, add the full bag, and mix for around five minutes to a smooth, even consistency; use a slow-speed paddle mixer for small quantities and a proper grout mixer for larger ones. Pour continuously from one side only, across the shortest travel, so a single grout front pushes air and water out ahead of it, and keep the head topped up throughout. Once placed, cure the exposed grout edges promptly with wet hessian, continuous water or a Fosroc curing membrane to prevent surface drying while strength develops.
Specifications
| Product type | Dual shrinkage-compensated, ultra-high-strength, high-flow cementitious grout |
| Standard compliance | ASTM C1107 Type C (packaged dry hydraulic-cement non-shrink grout) |
| Base chemistry | Portland cement, graded fillers and expansion additives; chloride-free, no metallic iron |
| Consistency | Free-flow / flowable, self-compacting, non-bleed |
| Maximum gap thickness | Up to 150 mm in a single pour |
| Yield | Approximately 11.5 litres per 25 kg bag at flowable consistency |
| Pack size | 25 kg moisture-resistant bags |
| Load capability | Suitable for both static and dynamic (vibrating) loads |
| Curing | Wet hessian, continuous water or curing membrane on exposed surfaces |
Industry use cases
Power generation
Grouting turbine, boiler feed pump and compressor base plates in thermal and gas power plants, where rotating equipment demands sustained full contact under dynamic load.
Bridges and infrastructure
Bedding bridge bearing pedestals and bearing plates so that traffic-induced cyclic loads transfer evenly without loss of contact at the bearing interface.
Heavy manufacturing
Foundations for large presses, compressors and machine tools where vibration and precise alignment make dual shrinkage compensation essential.
Process and petrochemical plants
Grouting pump, blower and reciprocating compressor skids in refineries and process facilities that run continuously under fluctuating loads.
Precast and structural
Column base grouting and precast connection filling where high load transfer and non-shrink performance are specified.
Frequently asked questions
What is the difference between Conbextra GP5 and GP2?
What is the maximum thickness I can pour in one go?
How much water do I add and how much does a bag yield?
Can Conbextra GP5 handle vibrating machinery?
Is it corrosive to anchor bolts or does it stain concrete?
When should I use an epoxy grout instead?
How we position Fosroc Conbextra GP5
Within the Fosroc Conbextra range, GP5 is the ultra-high-strength rung: step down to Conbextra GP2 for standard precision grouting under lighter or predominantly static loads, or to GP2N where lower exothermic heat is wanted on larger pours. Where the exposure turns aggressive, the loads become extreme, or gaps are very thin, move across to Fosroc’s epoxy grouts such as Conbextra EP 300 or the EP bearing grouts. Space Arc pairs GP5 with the supporting Fosroc system it is usually specified alongside, including Nitobond epoxy bonding agents at construction joints and Concure or Nitocote curing and protection products for the surrounding concrete. Because Space Arc distributes across brands, we can also cross-reference equivalent non-shrink grouts from MC-Bauchemie (Emcekrete) and Sika (SikaGrout) where a project’s approved-vendor list calls for them, while keeping the specification technically like-for-like.
Related Grouts & Anchors products
Source Fosroc Conbextra GP5 for your project
Authorised distribution, technical advice & professional application across Delhi NCR and Pan-India.